A06B-6102-H222
Description
1. General Information
Part Number: A06B-6102-H222 (#H520)
Model: αi SPM‑22 (Spindle Amplifier Module, 200 V class)
Brand: FANUC
Application: High‑power spindle drive for CNC lathes, machining centers, heavy‑duty milling; supports rigid tapping, Cs contouring
Communication: FSSB (FANUC Serial Spindle Bus, fiber‑optic)
Mounting: Vertical, cabinet‑mounted (screw‑fixed)
Weight: Approx. 15 kg
Manual Number: B‑65162 (instruction), B‑65285E (maintenance)
2. Electrical Ratings
DC Bus Input: 283–325 VDC (from αi PSM power supply)
Rated Output Power: 25.2 kW
Rated Output Current: 95 A (3‑phase)
Max Output Current: 120 A
Output Voltage: 3‑phase AC 230 V
Input Frequency: 50/60 Hz
Cooling: Built‑in forced air cooling (internal fan)
Operating Temperature: 0 °C to +55 °C
Storage Temperature: −20 °C to +60 °C
Protection Class: IP20 (indoor use)
Certification: CE approved
3. Compatibility
CNC Systems: 0i‑MF/TF, 16i/18i/21i, 30i‑B (FSSB interface)
Spindle Motors: αi series (αiS/αiF/αiM) 22 kW class (200 V)
Power Supply: A06B‑6091/6134 series (αi PSM)
Feedback: αi spindle encoder (A/B/Z/Cs signals)
4. Connector Description
CXA2A: 24 VDC control power, alarm output
FSSB IN/OUT: Fiber‑optic communication (CNC ↔ amplifier)
CN1: Spindle encoder feedback
CN2: Spindle motor power (U/V/W)
P/N: DC bus (+/−), regenerative resistor terminals
PE: Protective earth (ground)
5. Protection Functions
Overvoltage / Undervoltage protection
Overcurrent / Short‑circuit protection
Overtemperature protection (main circuit / motor)
Fan failure detection
DC link fuse blown detection
Motor overspeed / speed error alarm
6. Key Features
High‑power 25.2 kW output for heavy machining
Fiber‑optic FSSB for high noise immunity and simplified wiring
High‑speed response; supports rigid tapping and Cs contouring
Built‑in self‑diagnostics with LED status and alarm codes
Compact, high‑density design for cabinet space optimization
7. Typical Alarm Codes
1: Motor overheat
3: Excessive speed error
5: Power supply fuse blown
7: Overspeed
12: Overcurrent in power circuit
36: Overflow error counter
Get a Quote