A06B-6102
Description
1. General Information
Part Number: A06B-6102‑H122 / H222 / H226 (#H520)
Model: αi SPM‑22 / SPM‑26 (Spindle Amplifier Module)
Brand: FANUC
Application: High‑speed/high‑power spindle drive for CNC lathes, machining centers, high‑precision milling
Communication: FANUC Serial Spindle Bus (fiber‑optic or cable)
Mounting: Vertical, cabinet‑mounted (screw‑fixed)
Manual Number: B‑65162 (instruction) / B‑65285E (maintenance)
2. Electrical Ratings (Common)
DC Bus Input Voltage: 283–325 VDC (from αi PSM power supply)
Output Voltage: 3‑phase 230 VAC
Cooling: Built‑in forced air cooling (internal fan)
Operating Temperature: 0 °C to +55 °C
Storage Temperature: −20 °C to +60 °C
Protection Class: IP20 (indoor use)
3. Model Variations (A06B-6102‑xxx)
A06B-6102‑H122 (#H520) – SPM‑22 Type 4
Rated Power: 22 kW
Rated Output Current: 85 A
Features: Cs contour control, high‑resolution internal circuit
A06B-6102‑H222 (#H520) – SPM‑22
Rated Power: 25.2 kW
Rated Output Current: 95 A
Max Output Current: 120 A
A06B-6102‑H226 (#H520) – SPM‑26
Rated Power: 29.8 kW
Rated Output Current: 111 A
Max Output Current: 140 A
4. Protection Functions
Overvoltage / Undervoltage protection
Overcurrent / Short‑circuit protection
Overtemperature protection (main circuit / motor)
Fan failure detection
DC link fuse blown detection
Motor overspeed / speed error alarm
5. Connector Description
CXA2A: 24 VDC control power, alarm output
FSSB IN/OUT: Fiber‑optic communication (CNC ↔ amplifier)
CN1: Spindle encoder feedback
CN2: Spindle motor power (U/V/W)
P/N: DC bus (+/−), regenerative resistor terminals
PE: Protective earth (ground)
6. Compatibility
CNC Systems: 0i‑MF/TF, 16i/18i/21i, 30i‑B (FSSB interface)
Spindle Motors: αi series (αiS/αiF/αiM) 22–26 kW class
Power Supply Unit: A06B‑6091/6134 series (αi PSM)
Feedback: FANUC αi spindle encoder (A/B/Z/Cs signals)
7. Key Features
High‑power spindle control (22–30 kW) for heavy machining
Fiber‑optic FSSB for high noise immunity and simplified wiring
High‑speed response, support for rigid tapping and Cs contouring
Built‑in self‑diagnostics with LED status and alarm codes
Compact, high‑density design for cabinet space optimization
8. Typical Alarm Codes
1: Motor overheat
3: Excessive speed error
5: Power supply fuse blown
7: Overspeed
12: Overcurrent in power circuit
36: Overflow error counter
Get a Quote