51306773175
May 22, 2026

51306773175

The 51306773‑175 (CC‑TAID01) is a Series C Analog Input Field Termination Assembly (FTA) for Honeywell TDC3000, TPS, and Experion PKS DCS platforms. It provides isolated, high‑precision analog signal conditioning for 4–20 mA / 0–10 V field transmitters, routing clean signals to the control system.

Description

Product Overview

The 51306773‑175 (CC‑TAID01) is a Series C Analog Input Field Termination Assembly (FTA) for Honeywell TDC3000, TPS, and Experion PKS DCS platforms. It provides isolated, high‑precision analog signal conditioning for 4–20 mA / 0–10 V field transmitters, routing clean signals to the control system.

General Information

  • Part Number: 51306773175 (51306773‑175)

  • Alternate PN: CC‑TAID01

  • Module Type: Analog Input FTA (Field Termination Assembly)

  • Compatible Systems: Honeywell TDC3000, TPS, Experion PKS (UCN)

  • Manufacturer: Honeywell

  • Status: Discontinued (EOL); new surplus, refurbished, and used units available

  • Origin: United States

  • Certification: CE, UL, CSA; conformal coated for harsh environments

Technical Specifications

  • Input Signals: 4–20 mA, 0–20 mA, 0–10 V, ±10 V (configurable)

  • Channels: 8 or 16 isolated analog inputs (model‑dependent)

  • Resolution: 16‑bit

  • Accuracy: ±0.1% full scale at 25°C

  • Isolation: 1500 VAC channel‑to‑channel, channel‑to‑backplane

  • Input Impedance: 250 Ω (current), >1 MΩ (voltage)

  • Power Requirement: 24 VDC (15–30 VDC), ≤5 W

  • Operating Temperature: ‑20°C to +60°C (‑4°F to 140°F)

  • Storage Temperature: ‑40°C to +85°C (‑40°F to 185°F)

  • Humidity: 10%–90% RH, non‑condensing

  • Dimensions: 140 mm × 80 mm × 50 mm

  • Weight: Approx. 0.75 kg

Key Features

  1. High‑Density Isolated Inputs: Accepts multiple 4–20 mA / 0–10 V transmitter signals with full channel isolation to eliminate ground loops.

  2. Industrial‑Grade Reliability: Conformal coated PCB, wide temperature tolerance, and robust construction for chemical, power, oil & gas, and pulp & paper plants.

  3. Precision Signal Conditioning: 16‑bit resolution and ±0.1% accuracy ensure accurate monitoring of pressure, flow, level, and temperature.

  4. Fault Detection: Built‑in open/short‑circuit detection for field wiring and transmitters, with LED status indicators.

  5. Seamless Integration: Standard Series C form factor for easy installation in UCN I/O chassis; supports hot‑swapping in redundant systems.

Applications

  • Process Industries: Chemical, petrochemical, power generation, oil & gas, pulp & paper, pharmaceuticals.

  • System Role: Primary analog input interface for Honeywell UCN/TDC3000 DCS.

  • Typical Uses:

    • Monitoring pressure, flow, level, and temperature transmitters.

    • High‑density analog signal multiplexing in large process plants.

    • Accurate data acquisition for closed‑loop control systems.

Installation & Wiring

  1. ESD Precautions: Use anti‑static wristbands and ESD‑safe work surfaces.

  2. Power Off: De‑energize the I/O chassis before inserting/removing the module.

  3. Chassis Installation: Insert into a UCN I/O slot and secure with mounting screws.

  4. Field Wiring:

    • Connect 4–20 mA / 0–10 V transmitter wires to the compression terminals.

    • Use shielded twisted‑pair cable; maintain consistent cable length and polarity.

  5. Configuration: Use Experion PKS or TPS software to set signal type, range, and scaling parameters.

Maintenance

  • Periodic Inspection: Check LED status, terminal tightness, and 24 VDC power supply.

  • Cleaning: Remove dust with a dry, soft cloth; avoid liquid cleaners.

  • Fault Troubleshooting:

    • Verify transmitter wiring integrity and polarity.

    • Check for open/short circuits in field cables.

    • Use system diagnostics to identify faulty channels or wiring.

Safety Notes

  • Perform all installation and maintenance with chassis power disconnected.

  • Operate within rated temperature and humidity limits.

  • Do not modify or disassemble the module; this voids the warranty and may cause damage.

  • Comply with site ESD and safety procedures at all times.


Get a Quote