51304728175
May 22, 2026

51304728175

51304728175 (MC-GDID13) is a 32-channel Digital Input (DI) Field Termination Assembly (FTA) with Galvanic Isolation (GI), designed for Honeywell Experion PKS / C300 / C200 / TDC3000 DCS. It interfaces discrete field devices (switches, relays, sensors) to the DI I/O Processor (IOP), supporting 24VDC sink/source and harsh environment conformal coating (CC).

Description

1. Product Overview

51304728175 (MC-GDID13) is a 32-channel Digital Input (DI) Field Termination Assembly (FTA) with Galvanic Isolation (GI), designed for Honeywell Experion PKS / C300 / C200 / TDC3000 DCS. It interfaces discrete field devices (switches, relays, sensors) to the DI I/O Processor (IOP), supporting 24VDC sink/source and harsh environment conformal coating (CC).

2. Basic Information

  • Part Number: 51304728175 (51304728-175)

  • Model: MC-GDID13

  • Type: DI FTA, 32-channel, 24VDC, Galvanic Isolation (GI), Conformal Coating (CC), CE Certified

  • Compatible Systems: Experion PKS, C300, C200, TDC3000

  • Mounting: Standard 19-inch UCN I/O rack

  • Weight: Approx. 0.9 kg

  • Dimensions: 318 × 29 × 278 mm

3. Technical Specifications

  • Channels: 32 isolated digital inputs (2×16 groups)

  • Input Voltage: 24VDC nominal (18–30VDC operating range)

  • Input Type: Dry contact, sink (NPN)/source (PNP) compatible

  • Input Current: 10mA per channel @24VDC

  • Isolation: 500Vrms channel-to-chassis, 250Vrms channel-to-channel (galvanic)

  • Response Time: ≤1ms (ON/OFF)

  • Power Supply: 24VDC from backplane

  • Power Consumption: ≤9W

  • Operating Temperature: 0°C to +60°C

  • Storage Temperature: −40°C to +85°C

  • Humidity: 5%–95% RH, non-condensation

  • Coating: Conformal coating for G3 harsh environments

  • Certifications: CE, RoHS, UL, EMC compliance

4. Key Features

  1. 32-Channel High Density: Compact design saves cabinet space.

  2. Galvanic Isolation (GI): 500Vrms isolation blocks noise and ground loops.

  3. Conformal Coating (CC): Withstands humidity, dust, and corrosive gases.

  4. Sink/Source Universal: Works with NPN/PNP sensors and dry contacts.

  5. Fault Diagnosis: Detects channel open/short and module errors.

  6. Hot Swappable: Replace without system shutdown.

  7. LED Status: Per-channel and module health indicators.

  8. Redundant Compatibility: Matches redundant DI IOP for high availability.

5. Application Scope

Used in chemical, oil & gas, power generation, pharmaceutical, water treatment industries. Monitors limit switches, pressure switches, level switches, relay contacts, and proximity sensors for DCS logic/sequential control.

6. Installation Instructions

  1. Power Off: Disconnect rack power before installation/removal.

  2. Rack Insertion: Slide into UCN slot; secure with front screws.

  3. Field Wiring: Use shielded twisted-pair (22–24 AWG) per channel.

  4. Cable Separation: Keep signal cables ≥30cm from high-voltage lines.

  5. Shield Grounding: Single-point ground at FTA end to avoid loops.

  6. ESD Protection: Wear anti-static gloves/wrist strap during handling.

7. LED Indicator Description

  • PWR (Green): On = Normal 24VDC power.

  • RUN (Green): Flashing = Active IOP communication.

  • FLT (Red): On = Module fault; Flashing = Channel fault.

  • CH01–CH32 (Yellow): On = Input ON; Off = Input OFF.

8. Maintenance

  1. Monthly Inspection: Check wiring tightness and LED status.

  2. Cleaning: Use dry lint-free cloth only; no liquids/abrasives.

  3. Fault Handling: If FLT is on, check wiring/field devices; replace FTA if needed.

  4. Spare Parts: Use only original Honeywell 51304728175 units.

9. Safety Precautions

  1. Power-Only Work: Wiring/maintenance must be done with rack power off.

  2. Environmental Limits: Do not exceed rated temperature/voltage/humidity.

  3. No Modification: Do not open or modify internal components; voids warranty.

  4. Hazardous Areas: For IS use, follow approved wiring and barrier standards.


Get a Quote