51304672100
May 22, 2026

51304672100

Model 51304672100 is an 8-channel isolated analog output module, applied to Honeywell DCS system. It outputs standard 4-20mA current and 0-10V voltage signals to drive on-site control equipment.

Description

1. Product Overview

51304672100 (51304672-100) is an 8‑channel analog output module (HDW E type) for Honeywell DCS/industrial automation systems, providing 4–20 mA / 0–10 V precision analog signals to field actuators, transmitters and control devices.

2. Part Number & Revision

  • Model: 51304672100 (short: 51304672-100)

  • Hardware: HDW E1

  • Revision: D

  • Firmware: D 4‑05‑084‑6568

  • Weight: approx. 660–665 g

  • Dimensions: 320 × 30 × 280 mm

3. Technical Specifications

  • Number of Channels: 8 isolated analog outputs

  • Output Signals:

    • Current: 4–20 mA (sink/source)

    • Voltage: 0–10 V

  • Accuracy: ±0.1% FS (25 °C)

  • Resolution: 16‑bit

  • Load Capacity:

    • Current: ≤ 600 Ω

    • Voltage: ≥ 1 kΩ

  • Isolation: Channel‑to‑channel & channel‑to‑bus isolation

  • Power Supply: 24 VDC (from system backplane)

  • Operating Temperature: 0 °C to +60 °C

  • Storage Temperature: −40 °C to +85 °C

  • Certifications: CE, RoHS, UL (industrial control)

4. Key Features

  • 8‑channel high‑precision analog output for process control.

  • Robust industrial design for harsh environments.

  • Seamless integration with Honeywell DCS & control systems.

  • Short‑circuit & overload protection per channel.

  • LED status indicators for power, run, fault.

  • DIN rail / panel mount compatible.

5. Applications

  • Honeywell DCS (e.g., TDC3000, Experion) analog output subsystem.

  • Process industries: chemical, petrochemical, power, water treatment.

  • Industrial automation: manufacturing lines, HVAC, building control.

  • Precision control of valves, actuators, motor drives, transmitters.

6. Installation & Wiring

  1. Mounting: Install on standard DIN rail or control panel; ensure adequate ventilation (≥ 50 mm clearance).

  2. Backplane Connection: Insert module into Honeywell I/O rack; secure with locking screws.

  3. Field Wiring:

    • Use shielded twisted‑pair (STP) cable (22–18 AWG).

    • Connect shield to earth ground at one end only (control room side) to avoid ground loops.

    • Terminate per channel: +/− for current/voltage output.

  4. Wiring Precautions:

    • Separate analog cables from high‑voltage power cables (≥ 30 cm).

    • Avoid parallel routing with AC power lines.

7. Maintenance & Troubleshooting

  • Routine Inspection: Check for loose connectors, physical damage, or corrosion.

  • LED Status:

    • PWR (Green): On = power OK.

    • RUN (Green): Blinking = normal operation.

    • FLT (Red): On = fault (short circuit, overload, communication error).

  • Cleaning: Use dry cloth; avoid liquid cleaners.

  • Replacement: Use only Honeywell original parts; power off before removal/insertion.

8. Safety Precautions

  • Electrical Safety: Disconnect all power before installation/wiring/maintenance.

  • Environmental: Do not expose to moisture, dust, or corrosive gases beyond rated limits.

  • Modification: Do not alter module hardware or firmware; use Honeywell‑approved replacements only.

9. Ordering Information

  • Part Number: 51304672100 (51304672-100)

  • Description: Honeywell 8‑Channel Analog Output Module, HDW E1, Rev D

  • Compatible Systems: Honeywell DCS, Experion, TDC3000 & related I/O racks

Note: This is a consolidated English specification based on Honeywell public data and industrial distributor documentation. For the official Honeywell datasheet, contact your local Honeywell representative or visit the official website.
要不要我把这份英文说明书整理成可直接打印的一页 PDF 版?
不要图片

Honeywell 51304672100 Instruction Manual

1. Product Overview

Model 51304672100 is an 8-channel isolated analog output module, applied to Honeywell DCS system. It outputs standard 4-20mA current and 0-10V voltage signals to drive on-site control equipment.

2. Basic Parameters

Part Number: 51304672100
Channel Quantity: 8 isolated output channels
Output Signal: 4-20mA, 0-10VDC
Basic Accuracy: ±0.1% full scale
Resolution: 16 bit
Power Supply: 24VDC backplane power supply
Working Temperature: 0℃ ~ 60℃
Storage Temperature: -40℃ ~ 85℃
Load Resistance: Max 600Ω for current output, min 1kΩ for voltage output
Isolation Performance: Isolation between channels and internal bus

3. Main Features

  1. High precision and stable signal transmission

  2. Independent overcurrent and short circuit protection for each channel

  3. LED indicators display power, running and fault status

  4. Standard rack installation, easy assembly and replacement

  5. Good anti-interference performance, adapt to harsh industrial environment

  6. Compliant with CE, RoHS and UL industrial safety standards

4. Application Scope

Suitable for chemical, electric power, petroleum, water treatment and automatic production industries. Match Honeywell Experion and TDC3000 control systems to control valves, actuators and transmitters.

5. Installation Instruction

  1. Cut off system power before installation and disassembly.

  2. Insert the module into designated position of I/O rack and fix locking device.

  3. Adopt shielded twisted pair cable for field wiring.

  4. Keep analog wire away from high voltage power cable, separation distance no less than 30cm.

  5. Ground cable shield only at control cabinet side to prevent ground loop.

6. Indicator Description

PWR Green Light: Steady on means normal power supply
RUN Green Light: Flashing means normal operating state
FLT Red Light: Light on indicates circuit fault, overload or communication error

7. Maintenance Rules

  1. Regularly check connector tightness and module surface damage.

  2. Clean dust with dry cloth, do not use corrosive liquid.

  3. Stop operation immediately once fault alarm appears.

  4. Only original Honeywell spare parts can be used for replacement.

8. Safety Notice

  1. All wiring and maintenance work must be carried out under power-off state.

  2. Do not use beyond rated temperature and load range.

  3. Do not disassemble or modify internal structure of the module.

  4. Avoid damp, dusty and corrosive working environment.


Get a Quote