Manufacturer: Reliance Electric (Rockwell Automation) Part Number: 0-51811-1 (0518111) Product Type: Voltage Test Module / Diagnostic Card Application: MaxPak Plus, VS Spindle Drives, legacy Reliance drive systems Function: In‑system voltage measurement, signal diagnostics, calibration, and troubleshooting of drive power & control circuits Status: Obsolete; available as used / refurbished / new old stock Warranty: 12 months (refurbished / tested units)

Description

1. General Information

  • Manufacturer: Reliance Electric (Rockwell Automation)

  • Part Number: 0-51811-1 (0518111)

  • Product Type: Voltage Test Module / Diagnostic Card

  • Application: MaxPak Plus, VS Spindle Drives, legacy Reliance drive systems

  • Function: In‑system voltage measurement, signal diagnostics, calibration, and troubleshooting of drive power & control circuits

  • Status: Obsolete; available as used / refurbished / new old stock

  • Warranty: 12 months (refurbished / tested units)

2. Electrical Specifications

  • Power: +5 VDC, ±15 VDC (from drive backplane)

  • Measurement Ranges: AC/DC voltage, 0–600 VDC, 0–480 VAC

  • Input Impedance: High impedance (>1 MΩ) to avoid loading circuits

  • Accuracy: ±0.5% full scale

  • Isolation: 1000 VDC (test points to logic)

  • Protection: Overvoltage, transient, ESD protection

  • Test Points: Front‑panel accessible voltage / signal test jacks

3. Physical & Mechanical

  • Form Factor: Standard Reliance rack‑mount module

  • Dimensions (W×H×D): ~220 × 150 mm

  • Weight: ~0.7–0.9 kg

  • Front Panel: Test jacks, LED indicators, calibration potentiometers

  • Connectors: Edge connector (backplane), front‑panel test ports

  • Construction: Industrial FR4 PCB, conformal coated

4. Environmental Ratings

  • Operating Temp: 0°C to +60°C

  • Storage Temp: -20°C to +70°C

  • Humidity: 5%–95% RH, non‑condensing

  • Vibration: 10–150 Hz, 0.1 mm amplitude (cabinet rated)

5. Compatibility

  • Drive Systems: MaxPak Plus, VS Spindle Drives, FlexPak 3000, GV3000

  • Related Modules: 0-51805-5 (pulse input), 0-51772-3R (control board)

  • Replacement: Direct replacement for same series; no firmware differences

6. Installation & Usage

  1. Power Off: Disconnect drive power before inserting/removing.

  2. Rack Slot: Insert into dedicated drive rack slot; secure with retainers.

  3. Connections: Plug into backplane; use front‑panel jacks for probes.

  4. Operation: Power up; select test points; read voltage/ signal levels.

  5. Calibration: Adjust onboard pots for meter accuracy if needed.

  6. Common Uses: Check DC bus, control voltages, sensor signals, I/O status.


Get a Quote