0-51772-3R
Description
1. General Information
Manufacturer: Reliance Electric (Rockwell Automation)
Part Number: 0-51772-3R (also written as 0517723R)
Product Type: Drive Control PCB / System Interface Board
Series: 0-51772-xR (includes 0-51772-1R, 0-51772-9R, etc.)
Application: Reliance FlexPak 3000, GV3000, AutoMax DCS drives & legacy automation systems
Function: Signal conditioning, feedback processing, drive logic control, I/O interfacing
Status: Obsolete (discontinued); available as used / refurbished / new old stock
Warranty: 12 months (refurbished)
Marking: “0-51772-3R”, Reliance Electric logo, revision code
2. Electrical Specifications
Backplane Power: +5 VDC, ±15 VDC
Power Consumption: ~3–6 W
Signal Interfaces: Analog inputs (0–10 VDC, 4–20 mA), digital I/O (24 VDC logic), encoder / resolver feedback ports
Isolation: 500 VDC (signal-to-logic)
Protection: Overvoltage, surge, reverse polarity, ESD protection
Connector: Edge connector (backplane), screw terminals / header pins (field)
3. Physical & Mechanical
Dimensions (W × H × D): Standard Reliance card size (~220 × 150 mm)
Weight: Approx. 0.7–0.9 kg
Form Factor: Rack-mount PCB for Reliance standard 19” / subrack chassis
Construction: Industrial-grade FR4 PCB, conformal coated (moisture/dust resistance)
Components: Through-hole & surface-mount devices, electrolytic capacitors, power transistors, opto-isolators
4. Environmental Ratings
Operating Temperature: 0°C to +60°C (industrial range)
Storage Temperature: -20°C to +70°C
Humidity: 5%–95% RH, non-condensing
Vibration: 10–150 Hz, 0.1 mm amplitude (control cabinet rated)
5. Compatibility
Drive Systems: FlexPak 3000 DC drives, GV3000 AC drives, AutoMax DCS 5000
Related Boards: 0-51668-1 (process control interface), 0-51486-17 (analog input), 0-51771-7R (control logic)
Replacement: Direct replacement for 0-51772-1R / -9R (same form/fit, minor firmware differences)
6. Installation & Notes
Power Off: Disconnect all system power before insertion/removal.
Rack Slot: Insert into dedicated Reliance drive rack slot; secure with card retainers.
Wiring: Connect field signals (analog/digital/feedback) to designated terminals.
Verification: Confirm ±15 VDC and +5 VDC at backplane connector; check LED status indicators post power-up.
Common Issues: Capacitor aging, solder joint fatigue, connector oxidation (refurbished units include reflow & component replacement).
Get a Quote