0-51445
Description
1. General Information
Manufacturer: Reliance Electric (Baldor‑Reliance / Rockwell Automation)
Part Number: 0‑51445 (also 0‑51445‑A, 051445)
Product Type: Emitter Follower Card / Gate Driver Interface Board
Application: Reliance S3 / ImPak Plus series DC variable speed drives
Function: Buffers and amplifies control signals; provides isolated gate drive for SCR power bridge; improves drive stability and noise immunity
Status: Obsolete (OEM discontinued); available as used / refurbished
Warranty: 6–12 months (refurbished units)
2. Electrical Specifications
Input Signal: Low‑level logic/analog control signals from main control board
Output Drive: Isolated SCR gate firing pulses (6‑channel compatible)
Control Supply: +15 VDC / −15 VDC (from drive power supply board, e.g., 0‑51444)
Isolation Voltage: 2500 VAC (control‑to‑power isolation)
Onboard Protection:
Fast‑acting fuses
Transient voltage suppression (TVS)
Overcurrent limiting
Signal Bandwidth: DC to 10 kHz
Max Drive Current: 500 mA per channel
3. Physical & Mechanical
Dimensions (L × W × H): 220 × 35 × 25 mm (8.7 × 1.4 × 1.0 in)
Weight: Approx. 0.2 kg (0.44 lbs)
Construction: Long, narrow industrial PCB with conformal coating (dust/moisture resistance)
Key Components:
High‑speed power transistors
Opto‑isolators
Pulse transformers
Surface‑mount resistors/capacitors
Connection: Edge connector + flying lead wiring to SCR stack
4. Environmental Ratings
Operating Temperature: 0°C to +50°C (32°F to 122°F)
Storage Temperature: −20°C to +70°C (−4°F to 158°F)
Humidity: 5%–95% RH, non‑condensing
Vibration: Industrial grade (cabinet mounting)
5. Compatibility
Matched Main Control Board: 0‑51381 series
Matched Power Supply Board: 0‑51444
Matched Gate/Trigger Boards: 0‑51419, 0‑51422, 0‑51423
Drive Models: S3, ImPak Plus, VS series DC drives
6. Installation Notes
Disconnect all AC/DC power before installation or service.
Mount board in designated drive slot; secure flying leads to SCR gate terminals.
Verify control supply voltages (+15 VDC / −15 VDC) are within ±5% tolerance.
Check pulse transformer wiring phasing before energizing drive.
After installation, test for proper SCR firing and drive rotation direction.