0-50004-R
May 21, 2026

0-50004-R

Manufacturer: Reliance Electric (Rockwell Automation) Part Number: 0-50004-R (alternate: 050004R) Type: DC Amplifier Card (直流放大卡) Series: SealPak (密封式直流驱动控制系统) Function: High-gain DC signal amplification, power drive for control loops Status: Obsolete / Discontinued (repair & surplus only) NSN: 5996-00-827-3660

Description

Basic Information

  • Manufacturer: Reliance Electric (Rockwell Automation)

  • Part Number: 0-50004-R (alternate: 050004R)

  • Type: DC Amplifier Card (直流放大卡)

  • Series: SealPak (密封式直流驱动控制系统)

  • Function: High-gain DC signal amplification, power drive for control loops

  • Status: Obsolete / Discontinued (repair & surplus only)

  • NSN: 5996-00-827-3660

Electrical Specifications

  • Control Power: ±15 VDC (SealPak bus), +5 VDC logic

  • Input Signal: ±10 VDC (low-level analog)

  • Output Signal: ±10 VDC (high-current drive, up to 200 mA)

  • Gain Range: 10–1000 (adjustable via front pot)

  • Bandwidth: DC to 15 kHz

  • Accuracy: ±0.1% FSR

  • Protection: Short-circuit, overcurrent, thermal shutdown

  • Isolation: Galvanic isolation (I/O ↔ logic ground)

Mechanical & Environmental

  • Mounting: Standard SealPak slot-mount (slide-in + front lock screw)

  • Dimensions (L×W×H): 279 × 216 × 178 mm

  • Weight: Approx. 1.4 kg (3.0 lbs)

  • Operating Temp: 0°C to 55°C (32°F to 131°F)

  • Storage Temp: -25°C to 65°C (-13°F to 149°F)

  • Humidity: 5%–95% non-condensing

  • Coating: Conformal coated PCB (dust/moisture resistance)

Key Features

  • High-Gain DC Amplification: Precision gain for low-level signal boosting

  • Front-Panel Adjustment: Gain potentiometer; LED status (Power, Fault)

  • Heavy-Duty Output: Drives multiple control cards or power stages directly

  • Fault Protection: Self-protects against short circuits and overloads

  • Harsh Environment Ready: Sealed design for industrial floor use

Compatible Systems & Replacement

  • System: SealPak DC drive racks (legacy, paired with 0-50001-2R control card)

  • Matched Modules: 0-50001-2R (control), 0-50005 (I/O), 0-50010 (power)

  • Replacement: Direct replacement for older SealPak 0-50004 (non-R version)

Installation & Calibration

Installation

  1. Power off the SealPak rack.

  2. Insert 0-50004-R into an empty slot; tighten front locking screw.

  3. Verify ±15 VDC and +5 VDC bus power.

Calibration

  1. Power on; confirm Power LED is ON.

  2. Apply a known ±10 VDC input signal.

  3. Adjust Gain pot to get the desired output amplitude.

  4. Check output current (≤200 mA) for stability.

  5. Lock potentiometer; test under load.

Operation & Faults

  • Normal: Power LED ON; stable output; no fault triggers.

  • Fault LED ON: Short circuit, overcurrent, or thermal trip (reset after clearing fault).

  • No Output: Check bus power, wiring, on-board fuse, or input signal.


Get a Quote