Part Number: 490051, 0-49005-1, O490051 Manufacturer: Reliance Electric (Rockwell Automation / ABB) Series: CardPAK Engineered DC Drives (similar to FlexPak / MinPak) Type: Linear Voltage Time Unit (LVTU) – closed‑loop voltage regulator / timing board

Description

1. General Information

  • Part Number: 490051, 0-49005-1, O490051

  • Manufacturer: Reliance Electric (Rockwell Automation / ABB / Baldor)

  • Series: CardPAK Engineered DC Drives (FlexPak / MinPak / MaxPak compatible)

  • Type: Linear Voltage Time Unit (LVTU) – closed‑loop voltage regulator & timing control board

  • Function: Precision linear voltage output, adjustable time delay, closed‑loop feedback regulation for DC drives

  • Status: Obsolete; refurbished / used units available

  • Mounting: CardPAK rack, standard 3U Eurocard slot

  • Related Manuals: CardPAK Instruction Manuals, Reliance DC Drive System Guides

2. Electrical Specifications

  • Backplane Supply: ±15 VDC (nominal)

  • Power Consumption: ≤ 5 W

  • Output Voltage Range: 0–10 VDC linear adjustable (or ±10 VDC configurable)

  • Regulation Mode: Closed‑loop voltage regulation with feedback

  • Time Delay Range: 0.1 second to 100 seconds (potentiometer adjustable)

  • Linearity: ±0.1% of full scale

  • Temperature Coefficient: ±50 ppm/°C

  • Adjustments: Onboard potentiometers for Gain, Offset, Time Constant

  • Indicators: Power LED, Fault LED, Active LED

  • I/O Interface: Edge connector (backplane); front header for field wiring

3. Mechanical Specifications

  • Form Factor: 3U Eurocard

  • Dimensions (W × H × D): 100 mm × 160 mm × 30 mm

  • Weight: Approximately 0.45 kg

  • Construction: Conformal coated PCB, industrial grade, metal front panel

  • Connector: Edge finger (backplane); front header for external I/O

4. Environmental Ratings

  • Operating Temperature: 0 °C to +55 °C

  • Storage Temperature: −20 °C to +70 °C

  • Humidity: 10%–90% RH, non‑condensing

  • Vibration: 10–100 Hz, 0.1 mm amplitude (operational)

  • Certifications: UL, CSA, CE

5. Key Features

  • Precision linear voltage regulation: 0–10 VDC adjustable output

  • Integrated time‑delay functions: 0.1–100 seconds for sequencing and coordination

  • Closed‑loop feedback: fast response to load changes, tight voltage stability

  • Compact 3U Eurocard design: fits standard CardPAK racks, hot‑swap capable

  • Onboard trim potentiometers: easy field calibration (Gain, Offset, Time)

  • Industrial robustness: conformal coating, wide temperature range, vibration resistance

6. Compatibility

  • Racks: CardPAK 6‑slot, 12‑slot, 18‑slot

  • Drives: Reliance Electric FlexPak, MinPak, MaxPak DC drive systems

  • Interchangeability: 0-49005-1 / 490051 fully interchangeable

  • Cross‑reference: 0-49005-5 (similar model, different timing range)