31C022-503-4-05
Description


1. Model Code Meaning
31C: MOVITRAC 31C compact series
022: 2.2 kW rated output power
503: 380–500 V AC, 3‑phase
4: 3‑phase input, built‑in brake chopper (4‑quadrant)
05: Standard configuration + integrated FBG31C keypad (RS485 Modbus, no fieldbus card)
2. Electrical Ratings
Rated Output Power: 2.2 kW
Input Voltage: 3‑phase AC 380–500 V, 50/60 Hz
Rated Input Current: 5.9 A
Rated Continuous Output Current: 5.9 A
Output Voltage: 0–480 V 3‑phase AC
Output Frequency: 0–400 Hz
Control Modes: V/F open‑loop / Sensorless vector (SLV)
Overload: 150% / 60 s
Switching Frequency: 4 / 8 / 12 / 16 kHz (selectable)
Safety: STO (Safe Torque Off) standard
3. Mechanical & Environmental
Protection Class: IP20
Cooling: Natural convection (no fan)
Operating Temp: 0 °C to +45 °C (full load)
Storage Temp: −25 °C to +70 °C
Humidity: 5–95 %, non‑condensing
Mounting: Vertical wall‑mount
Altitude: ≤1000 m (no derating); 1%/100 m above 1000 m
Weight: approx. 2.8 kg
4. Interfaces (Standard)
Integrated FBG31C keypad (for local setup/operation)
RS485: Modbus RTU (onboard)
Analog Inputs: 0–10 V DC / 0–20 mA (2 inputs)
Digital Inputs: 6 × 24 V DC programmable
Relay Outputs: 2 × programmable (NO/NC)
PTC motor thermal input
Brake resistor connection terminals
Multi‑speed (fixed frequency) terminals
5. Main Functions
Acc/Dec time: 0.1–600 s
DC injection braking + dynamic braking (fast stop)
Energy‑saving mode
Control sources: keypad / terminals / Modbus
Slip compensation (stable speed under load)
Soft start/stop (reduce inrush & mechanical stress)
Built‑in PID (constant speed/pressure/flow)
Parameter save/copy/restore
Good low‑speed torque
6. Protection Features
Overcurrent / short‑circuit / earth fault
Overvoltage / undervoltage
Input phase loss
Inverter overtemperature
Electronic thermal motor protection
Stall prevention
ESD protection (control terminals)
Hardware STO (PL d, SIL2)
7. Installation & Wiring
Isolate power before wiring/service
Separate power and control cables (EMI reduction)
Reliable PE grounding required
Keep clearance for cooling
Avoid dust, humidity, oil, corrosive environments
Use shielded motor cables
8. Commissioning
Verify wiring & voltage match rating
Enter motor data (V, I, f, n)
Select control mode
Set acc/dec & frequency limits
No‑load test run
Load operation
9. Maintenance
Clean dust every 3–6 months
Check terminal tightness periodically
Monitor current & temperature during operation
Service by qualified personnel only
10. Applications
2.2 kW 3‑phase motor speed control
Conveyors, packaging, textile machinery
Fans, pumps (energy saving)
General light‑industrial variable‑speed drives
Systems with Modbus RTU & local keypad operation
11. Compliance
CE (Low Voltage)
EN 61800‑3 (EMC)
RoHS
STO: PL d, SIL2