31B055-503-4-00
Description

1. Model Code Decoding
31B = MOVITRAC 31B compact series (high‑power density)
055 = 55 kW rated output power
503 = 400 VAC (380–480 V) voltage class
4 = 3‑phase AC input
00 = standard firmware, no options
2. Electrical Ratings (400 V / 50–60 Hz)
Rated output power: 55 kW (3‑phase asynchronous motor)
Input: 3‑phase AC 380–480 V, 50/60 Hz ±5%
Rated input current: ~99 A
Rated output current: 110 A (continuous); 123.8 A (125% overload)
Output voltage: 0–480 VAC, 3‑phase
Output frequency: 0–400 Hz (V/f or sensorless vector)
Overload: 150% / 60 s; 125% continuous
Switching frequency: 2–16 kHz (adjustable)
Power factor: ≥ 0.95 at full load
Efficiency: ≥ 97% at rated load
Safety: STO (Safe Torque Off) PL d / SIL 2 (standard)SEW-EURODRIVE
3. Mechanical & Environmental
Protection class: IP20 (front panel)
Cooling: high‑performance built‑in fan, vertical mounting
Ambient temp: 0 °C … +45 °C (full power); up to +50 °C with derating
Storage temp: −25 °C … +70 °C
Humidity: 5–95 %, non‑condensing
Altitude: ≤ 1000 m (no derating)
Vibration: 10–55 Hz, 0.15 mm amplitude
Dimensions (W×H×D): 320 × 520 × 255 mm
Weight: 18.5 kg
4. Standard Interfaces & Terminals
Control & I/O
Analog input: 0–10 V DC / 0–20 mA (speed ref, 12‑bit)
Digital inputs: 6 × 24 V DC programmable (sink/source)
Relay output: 2 × programmable (250 V AC / 30 V DC, 3 A)
Motor thermistor: PTC/KTY input (overheat protection)
Communication
RS‑485 onboard (Modbus RTU / SEW internal bus)
Optional: PROFIBUS‑DP, Ethernet/IP, PROFINET
Keypad: DBG 31 (parameter setup & display)
Power Terminals
X1: L1/L2/L3 (3‑phase input)
X2: U/V/W (motor output) + PE
DBU: brake resistor connection (integrated brake chopper, 4‑quadrant)
5. Main Functions
V/f open‑loop or sensorless vector control (high torque at low speed)
4‑quadrant operation (integrated brake chopper for regenerative loads)
Accel/decel: 0.1–600 s adjustable (independent ramps)
Dynamic braking + DC injection braking (fast stop & holding)
Slip compensation (improves speed accuracy under load)
Multi‑step speed: up to 8 preset speeds (terminal selectable)
Built‑in PID (pressure/flow/speed closed‑loop control)
Energy‑saving mode (light‑load voltage reduction)
Parameter copy (keypad/communication for fast setup)
6. Protection Features
Overcurrent (instantaneous & thermal)
Overvoltage / undervoltage
Input phase loss detection
Inverter overtemperature (IGBT/heatsink)
Motor overload (electronic thermal relay)
Output short circuit & earth fault
Stall prevention (anti‑stall during acceleration)
Reverse polarity & ESD protection
STO safe torque off (hardware‑based safety, PL d / SIL 2)SEW-EURODRIVE
7. Installation & Wiring Notes
Mounting: vertical, ≥ 150 mm clearance top/bottom for airflow
Power cables: shielded 4‑core (L1/L2/L3/PE), ≥ 25 mm²
Motor cables: shielded, max length 100 m (with filter)
Control cables: twisted pair, shielded, routed separately from power cables
Grounding: PE ≤ 4 Ω, star grounding recommended
8. Compliance & Standards
CE (Low Voltage Directive 2014/35/EU)
EMC: EN 61800‑3, Category C2 (industrial environment)
RoHS 2011/65/EU compliant
STO: EN ISO 13849‑1 PL d, IEC 61508 SIL 2SEW-EURODRIVE
9. Typical Applications
Heavy‑duty conveyors & material handling
Large industrial fans & pumps (energy‑saving retrofit)
Crushers, mixers, extruders (high starting torque)
Textile, printing, packaging machinery
General‑purpose industrial drives (55 kW class)
Get a Quote