SEW BPS10-200-20-40-P-710 is a plate heat exchanger / heat exchange unit under the BPS10 series of SEW, designed specifically for industrial fluid heat exchange, cooling/heating, and waste heat recovery scenarios. It features a brazed plate structure, offering efficient heat exchange, compact durability, and compatibility with various media.
I. Basic Information
Product Series: BPS10 Brazed Plate Heat Exchanger
Full Model: BPS10-200-20-40-P-710
Structural Type: Brazed Plate (Stainless Steel + Copper Brazing)
Application Domains:
Hydraulic oil / lubricating oil cooling
Industrial water / ethylene glycol heat exchange
Refrigeration systems, air conditioners, heat pumps
Air compressor residual heat recovery
Injection molding machines, die-casting machines, hydraulic stations cooling
Material: 316 stainless steel plates + copper brazing
Protection Grade: IP54 (External Interfaces)
Installation Method: Vertical / Horizontal wall-mounted, bracket installation
II. Model Meaning Interpretation
BPS10: Series Code, Brazed Plate Heat Exchanger (Brazed Plate Heat Exchanger), 10 is the plate sheet specification
200: Plate Sheet Quantity 200 pieces (Core Parameter of Heat Exchange Area)
20: Single Flow Channel Design / Plate Sheet Spacing 2.0 mm
40: Interface Size DN40 (1.5 inches)
P: Interface Type: Thread / Flange (Standard Connection)
710: Design Pressure Grade 10 bar / Temperature Grade 70℃ (or corresponding specification code)
III. Core Technical Parameters
1. Heat Exchange and Fluid Parameters
Heat Exchange Area: Approximately 12.5 m² (200 sheets × single sheet surface 0.0625 m²)
Design Pressure: 10 bar (1.0 MPa)
Test Pressure: 15 bar (1.5 MPa)
Operating Temperature: -20℃ ~ +70℃
Maximum Flow Rate:
Primary Side: ≤ 40 m³/h
Secondary Side: ≤ 40 m³/h
Medium Compatibility:
Water, ethylene glycol, heat transfer oil, mineral oil
Weak acids and weak bases, clean fluids without solid particles
2. Structure and Dimensions
Plate Material: 316 stainless steel (Corrosion-resistant)
Brazing Material: Copper (Standard)
Interface Specification: DN40 (G1.5"/ 1.5" Thread)
Overall Dimensions (Width × Height × Depth): Approximately 250 × 750 × 120 mm
Weight: Approximately 28 kg
Flow Channel Form: Zigzag-shaped turbulent plate sheets (High Heat Exchange Efficiency)
3. Performance Characteristics
Heat Exchange Efficiency: K Value 3000–5000 W/(m²・K) (Water - Water Conditions)
Pressure Loss: ≤ 0.5 bar (Rated Flow)
Pressure Drop Control: Low Flow Resistance, High Heat Exchange Coefficient
Sealing Reliability: Fully brazed structure, no gaskets, no leakage
Anti-Vibration / Impact: Industrial Grade, Adapted to Equipment Vibration Environment
IV. Functions and Advantages
1. High Efficiency Heat Exchange
Zigzag-shaped turbulent plate sheets: Strengthen turbulence, high heat exchange coefficient
Compact Structure: Volume is 1/3–1/5 of shell and tube type, saving space
High Temperature Approach Degree: Small temperature difference heat exchange, significant energy saving
2. Durable and Reliable
316 Stainless Steel: Corrosion-resistant, anti-water hammer, long service life
Full Copper Brazing: No aging, no leakage, no maintenance required
Wide Operating Conditions Adaptability: Stable operation under temperature / pressure fluctuations
3. Installation and Maintenance
Lightweight: Easy to transport, easy to install
Interface Standardization: DN40 Thread, quick connection
No Wear Parts: Stable operation over the long term, low maintenance cost
4. Application Compatibility Hydraulic station cooling: Oil-water heat exchange, controlling oil temperature
Exhaust heat from air compressors: Recovering heat to heat water / provide heating
Injection molding machines / die-casting machines: Cooling of molds / oil fluid
Central air conditioning / heat pumps: Cooling / heating, temperature control of chilled water / hot water
Industrial circulating water: Cooling / heating, temperature control
V. Typical operating parameters (water - water)
Primary side (hot fluid)
Flow rate: 20 m³/h
Inlet temperature: 60℃
Outlet temperature: 40℃
Secondary side (cold fluid)
Flow rate: 25 m³/h
Inlet temperature: 25℃
Outlet temperature: 45℃
Heat exchange capacity: Approximately 465 kW
VI. Selection and installation tips
Medium cleanliness: No particles, no fibers, no impurities (it is recommended to install a filter)
Flow rate control: 0.5–2.0 m/s (optimal heat exchange range)
Installation direction: Vertical / Horizontal, avoid air blockage
Anti-freezing protection: Add antifreeze or empty the system in low-temperature environments
VII. Order information
Model: BPS10-200-20-40-P-710
Standard equipment: Heat exchanger body, interface plugs
Optional: Supports, filters, temperature sensors, pressure gauges
VIII. Application scenarios
Hydraulic system cooling: Machines, presses, construction machinery
Exhaust heat recovery from air compressors: Screw compressors, centrifugal compressors for energy saving
Plastic machinery: Injection molding, extrusion, die-casting oil temperature control
HVAC: Commercial buildings, factory heating and cooling
Food / Chemical: Heating / cooling of clean fluids (non-corrosive)
Get a Quote