ABB SACE E2S Air Circuit Breaker Description
November 23, 2026

ABB SACE E2S Air Circuit Breaker Description

ABB SACE E2S breaker for overload, short-circuit and earth-fault signal acquisition and protection logic judgment and LV main feeder on-off control and fault interruption output

Description

ABB SACE E2S Air Circuit Breaker Description

ABB SACE E2S is a high-performance intelligent air circuit breaker, rated current 800A, rated operational voltage 690V, rated short-time withstand current 65kA for 1 second, adopts PR122/P electronic trip unit supporting LSIG overload, short-circuit and earth-fault protection functions, equipped with built-in disturbance recording, high-precision energy metering and device self-diagnosis function, supports fixed-mounted or withdrawable draw-out installation structure, mates with ABB Ability power management system for remote monitoring, protection parameter configuration and fault data analysis. This ACB adopts optimized arc extinguishing chamber design, modular accessories for shunt release, undervoltage release and auxiliary contact position feedback monitoring function, widely used for main incoming feeder, transformer and heavy-load LV power distribution protection panels. It delivers reliable overload, short-circuit and earth-fault signal acquisition and protection logic judgment, stable LV main feeder on-off control and fault interruption output, and convenient breaker replacement for industrial low voltage power distribution systems.

Features ABB SACE E2S supports high short-circuit breaking capacity, flexible protection curve configuration and selective protection logic. Galvanic isolation separates primary high-current power circuit from secondary control and communication circuit to suppress surge and electromagnetic interference, standard withdrawable frame size fits low voltage switchgear cabinet layout, supports motor operating mechanism for remote electrical closing and opening and automatic transfer switching applications. The breaker maintains consistent overload, short-circuit and earth-fault signal acquisition and protection logic judgment and accurate LV main feeder on-off control and fault interruption output under continuous grid operation.

Technical Parameters ABB SACE E2S complies with IEC 60947-2 standards, supporting sustained overload, short-circuit and earth-fault signal acquisition and protection logic judgment, real-time LV main feeder on-off control and fault interruption output and straightforward breaker replacement during switchgear bay overhaul and commissioning.

Working Principle Three-phase current passes through built-in current transformers of ABB SACE E2S air circuit breaker. Electronic trip unit samples and calculates current value, compares measured value with protection setting threshold; once overload, short-circuit or earth fault condition reaches trip threshold, the trip mechanism rapidly opens main contacts to cut off fault circuit and records fault data for post-fault analysis. When current sensing, trip unit or operating mechanism assembly wears and fails, technicians isolate upstream power supply and carry out breaker replacement to resume normal overload, short-circuit and earth-fault signal acquisition and protection logic judgment and LV main feeder on-off control and fault interruption output.

Application Fields ABB SACE E2S is widely used in power plant auxiliary distribution, petrochemical main switchgear, mining heavy-load distribution and renewable energy low-voltage switchgear panels. It undertakes main incoming protection and switching tasks for industrial heavy-duty LV power distribution systems. This ABB SACE E2S air circuit breaker ensures dependable overload, short-circuit and earth-fault signal acquisition and protection logic judgment, stable LV main feeder on-off control and fault interruption output and easy breaker replacement for LV distribution renovation and EMAX spare part stocking projects.