ABB SACE EMAX2 E1.2 breaker for overload, short-circuit and earth-fault signal acquisition and protection logic judgment and LV main feeder on-off control and fault interruption output

Description

ABB SACE EMAX2 E1.2 Air Circuit Breaker Description

ABB SACE EMAX2 E1.2 is a compact intelligent air circuit breaker, rated current up to 1600A, adopts Ekip electronic trip unit supporting LSIG overload, short-circuit and earth-fault protection functions, equipped with built-in disturbance recording, high-precision energy metering and device self-diagnosis function, supports fixed-mounted or withdrawable draw-out installation structure, mates with ABB Ability energy management platform for remote monitoring, protection parameter configuration and fault data analysis. This ACB adopts optimized arc extinguishing chamber design, modular accessories for shunt release, undervoltage release and auxiliary contact configuration, widely used for main incoming feeder, transformer and heavy-load LV power distribution protection panels, especially suitable for limited cabinet space scenarios such as marine, offshore and compact switchgear. It delivers reliable overload, short-circuit and earth-fault signal acquisition and protection logic judgment, stable LV main feeder on-off control and fault interruption output, and convenient breaker replacement for industrial low voltage power distribution systems.

Features ABB SACE EMAX2 E1.2 supports high short-circuit breaking capacity, flexible protection curve setting and selective protection logic. Galvanic isolation separates primary high-current power circuit from secondary control and communication circuit to suppress surge and electromagnetic interference, compact frame size fits standard switchgear cabinet layout, supports motor operating mechanism for remote electrical closing and opening and automatic transfer switching applications. The breaker maintains consistent overload, short-circuit and earth-fault signal acquisition and protection logic judgment and accurate LV main feeder on-off control and fault interruption output under continuous grid operation.

Technical Parameters ABB SACE EMAX2 E1.2 complies with IEC 60947-2 standards, supporting sustained overload, short-circuit and earth-fault signal acquisition and protection logic judgment, real-time LV main feeder on-off control and fault interruption output and straightforward breaker replacement during switchgear bay overhaul and commissioning.

Working Principle Three-phase current passes through built-in current transformers of ABB SACE EMAX2 E1.2 air circuit breaker. Electronic trip unit samples and calculates current value, compares measured value with protection setting threshold; once overload, short-circuit or earth fault condition reaches trip threshold, the trip mechanism rapidly opens main contacts to cut off fault circuit and record fault data for post-fault analysis. When current sensing, trip unit or operating mechanism assembly wears and fails, technicians isolate upstream power supply and carry out breaker replacement to resume normal overload, short-circuit and earth-fault signal acquisition and protection logic judgment and LV main feeder on-off control and fault interruption output.

Application Fields ABB SACE EMAX2 E1.2 is widely used in power plant auxiliary distribution, petrochemical plant, marine and offshore, data center and renewable energy low-voltage switchgear panels. It undertakes main incoming protection and switching tasks for space-saving LV power distribution systems. This ABB EMAX2 E1.2 air circuit breaker ensures dependable overload, short-circuit and earth-fault signal acquisition and protection logic judgment, stable LV main feeder on-off control and fault interruption output and easy breaker replacement for LV distribution renovation and EMAX2 spare part stocking projects.