Description

TERASAKI ELC-4A 2111212-2 Breaker Electronic Control Unit Description

Overview

TERASAKI ELC-4A 2111212-2 is a breaker electronic control unit developed by Terasaki for marine and industrial moulded case circuit breaker protection systems. This breaker electronic control unit monitors current sampling signals and executes overload, short-circuit and ground-fault protection logic for the breaker core. TERASAKI ELC-4A 2111212-2 adopts sealed metal housing and screw terminal layout suitable for shipboard vibration environments. It delivers reliable breaker protection calculation, stable breaker trip output and convenient breaker unit replacement for marine power distribution and machinery power supply panels.

Features

TERASAKI ELC-4A breaker electronic control unit has compact enclosed metal housing designed to withstand shock, vibration and humidity inside electrical cabinets on vessels. It continuously collects current signals from the breaker CT core, compares measured values against preset protection thresholds and sends trip commands to the breaker release coil. The internal circuit has anti-transient surge protection to avoid false tripping caused by power grid spikes. Its fixed mounting hole and terminal definition match the original breaker perfectly, supporting quick breaker unit replacement. The unit maintains consistent breaker protection calculation and accurate breaker trip output under long-cycle continuous operation.

Technical Parameters

TERASAKI ELC-4A breaker electronic control unit works with matched Terasaki MCCB current transformers. It processes three-phase load current data and triggers protection action for overload, short circuit and earth fault conditions. It complies with marine electrical certification standards and low-voltage distribution component specifications, supporting sustained breaker protection calculation, real-time breaker trip output and straightforward breaker unit replacement during cabinet overhaul and inspection.

Working Principle

Current signals sampled by the breaker CT are transmitted to TERASAKI ELC-4A breaker electronic control unit. The internal protection core calculates effective current values and judges whether the load exceeds the set protection threshold. When abnormal current is detected, the unit outputs trip signal to release the breaker and cut off the fault circuit. After the fault is cleared, the unit can be reset for normal power supply restoration. When internal component aging or protection drift occurs, technicians carry out breaker unit replacement to resume normal breaker protection calculation and breaker trip output.

Application Fields

TERASAKI ELC-4A 2111212-2 is widely used in cargo ships, passenger vessels and offshore platform power distribution cabinets. It undertakes main circuit overcurrent and short-circuit protection tasks for marine power systems. This breaker electronic control unit ensures dependable breaker protection calculation, stable breaker trip output and easy breaker unit replacement for marine electrical maintenance and spare part stocking projects.


Get a Quote