6200038
Description


2. Main Features
Model: 6200038
Working principle: Inductive type
Detectable object: Ferrous and non-ferrous metals
Supply voltage: 10–30 V DC
Output type: 3-wire DC
Maximum load current: ≤ 200 mA
Protection grade: IP67 dustproof and waterproof
Operating temperature: -25 °C to +70 °C
Built-in reverse polarity, overvoltage and short-circuit protection
Vibration resistance and stable long-term operation
3. Safety Precautions
Disconnect power before installation and wiring.
Do not apply voltage higher than 30 V DC.
Avoid reverse power connection to prevent permanent damage.
Keep away from high-power motors, transformers and strong magnetic fields.
Do not disassemble or modify the sensor housing.
Prevent heavy impact, oil contamination and long-term damp conditions.
4. Installation
Fix the sensor with mounting nut or fixed bracket.
Maintain standard sensing distance from the metal target.
Mount perpendicular to the detected surface for optimal performance.
Do not place extra metal parts near the sensing head.
Arrange cable routing properly; avoid sharp bending and pulling.
5. Wiring Definition
Brown : DC +10~30 V Power
Blue : DC 0 V GND
Black : Signal output
Shield : Ground only at controller side
6. Operation Instructions
Wire connection must follow the standard definition.
Power on, sensor enters standby status.
When metal enters effective detection range, indicator lights on and output activates.
When metal leaves, output resets and indicator turns off.
Can be directly connected to PLC, relay and automation controller input.
7. Troubleshooting
No indicator light: Check power supply and wiring connection.
Always output signal: Metal target too close or surrounding metal interference.
Signal unstable: Loose wiring, mechanical vibration or power fluctuation.
Indicator on but no output: Signal wire broken or load damaged.
8. Maintenance
Clean dust and iron scraps on sensing surface regularly.
Check mounting tightness and cable wear periodically.
Avoid long-term high temperature and corrosive gas environment.
Replace the sensor immediately if shell crack or cable aging occurs。