Honeywell 51109818100 Product Description
Description

Honeywell 51109818100 Product Description
Model: 51109818100 (Standard Model: 51109818-100)
Brand: Honeywell
Series: TDC 3000 / TPS / Experion PKS Distributed Control System
Type: System Redundant Power Supply Module
I. Product Overview
51109818-100 is the core redundant power supply module of Honeywell's TDC 3000 control system, specifically designed to provide stable and uninterrupted DC power supply for Universal Station (US), GUS operation stations, AXM application modules, and HM historical modules. As the 1+1 redundant hot standby power supply for the system, it ensures seamless switching without interruption in case of a single power supply failure, and is the key driving force for ensuring the continuous operation and no power outage of the entire DCS control network, operation interface, and data storage unit.
II. Core Specification Parameters
Type: Industrial-grade redundant switching power supply
Compatible systems: TDC 3000, TPS, Experion PKS, US/GUS operation stations, AXM, HM Input:
Input for communication: 85 ~ 264 VAC (global adaptive, 47 ~ 63 Hz)
DC input: 110 ~ 300 VDC
Output:
Main output: 5.1V DC / 30A (system logic, CPU, I/O bus)
Auxiliary output: 12V DC / 5A, -12V DC / 2A (operation station, disk, interface)
Total power: 250W (rated) / 300W (peak)
Redundancy feature: 1+1 fully redundant hot standby, load current sharing, fault switching < 1ms
Efficiency: > 88% (typical load)
Stabilization accuracy: ±1% (full load, full voltage, full temperature range)
Ripple noise: < 50mV p-p (5V output)
Protection functions: Overvoltage, overcurrent, overtemperature, short circuit, reverse connection, surge full protection
Isolation voltage: 3000 VAC (input - output - earth)
Physical characteristics:
Size: Standard DCS single-slot module (140mm × 35mm × 190mm)
Installation: 19-inch rack, supports hot swapping
Cooling: Intelligent air cooling, automatic speed adjustment
Enclosure: Fully metal shielding, anti EMI/EMC interference
Environmental parameters:
Operating temperature: -20°C ~ +70°C
Storage temperature: -40°C ~ +85°C
Humidity: 5% ~ 95% RH (no condensation)
Anti-vibration: 5 g peak (20 ~ 500Hz)
Reliability:
MTBF: > 1,200,000 hours
Certifications: UL, CE, CSA, Class I Div 2 explosion-proof
III. Functional Features
1. Full redundant hot standby architecture
Dual power supplies are completely independent, with full isolation of input/output/control circuits
Automatic load current sharing, dual power supplies evenly distribute the load, extending lifespan
Automatic fault diagnosis, the failed power supply exits immediately, without disturbance switching
Real-time monitoring of redundant status, supports remote alarm and status feedback
2. Ultra-wide voltage global compatibility
85-264VAC full voltage, compatible with global power grids
AC/DC dual input, meets special power supply requirements for power plants, petrochemicals, etc.
Compatible with all TDC 3000 operation stations and controllers
Direct replacement of old models such as 51109818-001/-002
3. Industrial-grade stable output
Ultra-low ripple, pure DC, protects precision circuits
Wide temperature stability, voltage does not drift under extreme conditions
Super isolation, blocks on-site surges and ground potential differences
Multiple protections, automatically shuts down in any abnormal situation, maintenance-free
4. Intelligent diagnosis and maintenance
LED status indication (PWR, OK, FAULT, REDUNDANT)
Hot-swappable design, online replacement does not affect system operation
Intelligent fan, low noise, long life, dustproof, moisture-proof
Remote monitoring, supports system software reading of voltage, current, temperature
IV. Typical Applications
TDC 3000 US / GUS operation station - redundant power supply
AXM application module, HM historical module, UWS engineer station - power supply
LCN network nodes, control processor, I/O rack - auxiliary power supply
Chemical, petrochemical, power, metallurgy - critical DCS systems
Requirements for 7×24-hour uninterrupted operation in high-reliability scenarios
V. Model Comparison
51109818100: General material number
51109818-100: Standard 250W redundant power supply (main model)
51109818-001: Early 200W basic version (non-redundant)
51109818-200: 300W high-power enhanced version (heavy-load system) 51109818-300: Long-life Industrial Enhanced Version (Extreme Environment)
Get a Quote