Honeywell 621-6700 (6216700) Product Description
Description

Honeywell 621-6700 (6216700) Product Description
621-6700 (6216700) is an 8-channel, relay-type digital output module (DO) of the Honeywell 621 series I/O. It uses dry contact relays for output and is compatible with both AC and DC loads. It is compatible with traditional DCS systems such as 620/621 and TDC 3000.
I. Basic Information
Brand: Honeywell (Honeywell / ISSC)
Full Model: 621-6700 (6216700)
Series: 621 Series I/O Module (IPC 620/621, TDC 3000, UCN)
Type: 8-channel Relay Dry Contact Digital Output Module (DO)
Production Status: Out of Production (Second-hand / Repaired / Reconditioned Channel)
Weight: Approximately 0.6 kg
Dimensions: Approximately 11.8 × 4.7 × 9.4 cm
Installation: Inserted into the 621 Series I/O Rack
Isolation: Channel - System Side Relay Electrical Isolation
Common Suffix:
621-6700R: Supports Hot Swap
II. Core Functions
8 Channels Relay Dry Contact Output: Passive Contacts, Switchable AC/DC Load
SPDT (Single-Pole Double-Throw) Relay: Each Channel Contains NO/NC Contacts, Flexible Wiring
Wide Voltage Compatibility: Supports 30V DC and 250V AC Load Control
High Isolation Voltage: Relay Contacts - System Side Strong Electrical Isolation
LED Status Indication for Each Channel: Real-time Monitoring of Output On/Off
Overcurrent and Overheat Protection: Built-in Protection Circuit, Enhances Reliability
Compatible Systems: IPC 620, IPC 621, TDC 3000, UCN, etc. legacy DCS
III. Electrical Specifications
Output Type: SPDT Relay Dry Contact (Passive)
Channel Number: 8 Channels (Independent)
Contact Specifications:
Resistive Load: 2A @ 30V DC / 250V AC
Inductive Load: 1A @ 30V DC / 250V AC
Isolation Voltage: 2500V AC RMS (Contacts - System Side)
Action Time: ≤ 5 ms
Release Time: ≤ 3 ms
Contact Life: ≥ 1000,000 Times (Rated Load)
Power Supply: 5V DC (Backplane Bus Power Supply)
Protection Functions: Overcurrent Protection, Overheat Shutdown, Reverse Polarity Protection
IV. Environmental Parameters
Operating Temperature: 0°C ~ +60°C
Storage Temperature: -40°C ~ +85°C
Humidity: 5–95% RH (No Condensation)
Anti-Vibration: 10–55 Hz, 0.7 mm Double Amplitude
Protection: IP20 (Installed in Cabinet)
Certifications: CE, UL, CSA
V. Interfaces and Status
Field Interface: 50-pin D-Sub / European Terminal Block
LED Indicators:
PWR: Green (Normal Power Supply)
8 Channel LEDs: On = Bright, Off = Off
COM: Red (Common Terminal Abnormal / Bus Fault)
Bus Interface: 621 Rack-Specific Parallel Bus
VI. Typical Applications
AC/DC Mixed Load Control: 220V AC Contactors, 24V DC Valves
High-Power Circuit Switching: Motor Start/Stop, Heater Control, Large Current Valve Island
Safety Interlock Circuit: Emergency Stop, Fault Protection, Safety Door Interlock
Old System Upgrade: IPC 620/621, TDC 3000 System Relay Output Replacement
Industrial Automation Standard Scenarios: Production Line, Packaging Machine, Machine Tool, Chemical Plant
VII. Model Comparison (621 Series DO) Table
Parameters: 621-6700, 621-6550, 621-6650, 621-6503
Number of channels: 8 channels, 16 channels, 16 channels, 8 channels
Output type: Relay dry contact, 24V DC source type, 48V DC source type, 24V DC source type
Load voltage: 30V DC / 250V AC, 24V DC, 48V DC, 24V DC
Single channel current: 2A (resistive), 2A, 2A, 2A
Isolation method: Relay isolation, photoelectric isolation, photoelectric isolation, photoelectric isolation
Features: Passive contacts, applicable to AC and DC, 24V high density, 48V high voltage, large current self-protection
VIII. Common Faults and Troubleshooting
Relay does not act (LED does not light up)
Reason: Loose wiring, abnormal power supply on the backplane, module not plugged in tightly, bus fault
Troubleshooting: Measure the 5V on the backplane, reinstall the module, check the bus communication
Contact without output (conduction failure)
Reason: Contact oxidation, overload of the load, damage to the relay coil
Troubleshooting: Clean the contact, reduce the load current, replace the module
Output stuck (unable to disconnect)
Reason: Load short circuit, contact burnout, module overheating
Troubleshooting: Disconnect the load, check for short circuit fault, replace the module
IX. Related Models
8-channel relay output (hot-swappable): 621-6700R
24V DC source type output (16 points 2A): 621-6550
48V DC source type output (16 points 2A): 621-6650
24V DC source type self-protection output (8 points 2A): 621-6503
24V DC source type output (8 points 0.5A): 621-6500
Digital input: 621-4500, 621-4502, 621-4550
Analog input: 621-4000, 621-4001
Analog output: 621-5000, 621-5001
Get a Quote