PR6423/10R-030-CN+CON021
Description
I. Model Interpretation PR6423/10R-030-CN
PR6423: Φ8mm Eddy Current Sensor
10R: 10 meters of armored shielded cable
030: Standard sensitivity, standard linear calibration
CN: China-compatible version, with Chinese labels and domestic warranty compatibility
CON021: Special matching preamplifier, factory-matched for complete use together
II. Core Parameters of the Sensor
Probe Specifications: Diameter 8mm, M10×1 installation thread
Cable: 10m double-layer shielded armored, with anti-tensile, oil-resistant, and anti-electromagnetic interference properties
Linear Measurement Range: 0 - 1.5mm
Sensitivity: 12V/mm
Standard Installation Gap: 2.5mm
Matching Midpoint Voltage: Connect CON021 output -12V
Frequency Response: 0 - 12kHz
Coil Resistance: 4 - 6Ω
Insulation Resistance: > 100MΩ
Operating Temperature: Probe -35°C to +150°C
Protection Level: IP67
Compatible Target Materials: 42CrMo4 ferromagnetic alloy steel
III. Parameters of the CON021 Preamplifier
Power Supply: -24VDC (allowable range -18 to -30VDC)
Output Linear Range: -4V to -20V
Rated Power Consumption: ≤ 2W
Frequency Response: 0 - 10kHz
Built-in Protection: Reverse connection, short circuit, open circuit protection
Installation Method: Cabinet-mounted panel installation, protection level IP20
IV. Wiring and Connection
CON021 Terminal Definitions:
1 Terminal: -24V power negative
2 Terminal: 0V power ground
3 Terminal: Signal output (connected to TSI modules such as MMS6110/MMS6312)
4 Terminal: Signal common ground
Sensor and Preamplifier:
PR6423 comes with LEMO aviation connector, which can be directly inserted into the CON021 interface and tightened for locking.
Shielding Grounding Requirements:
Single-point grounding, only the front panel of the cabinet and preamplifier side are grounded, the shielding at the probe end is left floating, and grounding at both ends is prohibited.
V. On-site Installation and Commissioning
Probe should be vertically aligned with the measured shaft surface, avoiding the edge of the shaft
Initial Pre-set Installation Gap: 2.5mm
Power On Fine-tuning of the Probe Position to make the preamplifier output stable at -12V and then lock and fix
Cable should be kept away from power lines, frequency converters, and not laid parallel in the same slot as the power cable
VI. Voltage State Discrimination
Too Small Gap: Output close to -4V
Standard Working Point: 2.5mm ➜ -12V
Too Large Gap: Output close to -20V
No Voltage or Approaching 0V: Probe broken wire, LEMO connector loose, power polarity reversed
VII. Application Compatibility
Applicable Equipment: Steam turbines, compressors, fans, gas turbines
Measurement Functions: Shaft vibration, shaft displacement, eccentricity, phase monitoring
Compatible Systems: EPRO MMS6000, AMS6500 full series of TSI systems

Get a Quote