PR6423/002-030-CN+CON021
Description
I. Model Interpretation PR6423/002-030-CN
PR6423: Φ8mm Eddy Current Probe Series
002: With armored cable, length 3m
030: Standard range, standard sensitivity version
CN: Calibration for China Region / Chinese Label Version
CON021: Matching standard preamplifier (IP20, LEMO interface)
II. Parameters of PR6423/002-030-CN probe
Probe diameter: Φ8mm
Cable: 3m armored double shield, strong anti-interference
Linear range: 0 - 1.5mm (static ±1.0mm)
Sensitivity: 12V/mm (matched with CON021)
Recommended air gap: 2.5mm (corresponding to preamplifier - 12V)
Frequency response: 0 - 12kHz
Operating temperature: Probe -35℃ - +150℃; Cable -30℃ - +100℃
Coil resistance: 4 - 6Ω; Insulation resistance: >100MΩ
Suitable target materials: 42CrMo4 and other ferromagnetic steel, target surface diameter ≥ 25mm
III. Parameters of CON021 preamplifier
Power supply: -24VDC (-18 - -30VDC)
Output: -4V - -20V (linear range), with added vibration AC component
Mid-point voltage: -12V (air gap 2.5mm)
Power consumption: ≤2W
Frequency response: 0 - 10kHz (-3dB)
Protection: Open circuit / Short circuit / Reverse polarity protection
Protection: IP20 (installed in control cabinet)
Connection: Sensor end LEMO plug; Power / Output end screw terminals
IV. Complete wiring (terminal definitions are the same as before)
CON021 terminals:
1: -24V; 2: GND; 3: OUT (to MMS6110/MMS6312); 4: COM
Probe → Preamplifier: LEMO direct insertion locking, no adapter required
Shielding: Single-ended grounding (on the machine cabinet side), probe side shielding floating
V. Installation and commissioning key points
Air gap setting: 2.5mm → Output - 12V (optimal linearity)
Wiring: Away from power lines / frequency converters, parallel spacing ≥ 300mm
Compatible system: MMS6000 (MMS6110 vibration, MMS6312 speed / phase alignment), AMS6500 TSI
VI. Differences from PR6423/001-000
001-000: Short cable, no armor, suitable for short distance, low interference scenarios
002-030-CN: 3m armored cable, strong anti-interference, suitable for long-distance wiring in industrial sites