UAASWH-06CMU45 AC Spindle Motor Specification (Yaskawa External Air-Cooled Permanent Magnet Spindle Motor)
Description
UAASWH-06CMU45 AC Spindle Motor Specification (Yaskawa External Air-Cooled Permanent Magnet Spindle Motor)
1. Product Overview
2. Model Code Definition
UA = AC spindle classification; S = high-density laminated optimized stator core; W = standard three-phase industrial winding structure; H = lightweight reinforced cast housing design for compact machine installation
06 = Frame size code, corresponding to nominal 5.5kW(S3)/3.7kW(S1) rated power grade
C = Custom narrow-range winding tailored for regional 200V industrial power grid fluctuation matching
M = Built-in multi-turn absolute high-resolution serial feedback encoder for spindle positioning and rigid tapping control
U = Upgraded anti-impact heavy-duty rolling bearing assembly for frequent start-stop and intermittent rough cutting
45 = Exclusive custom mechanical specification code: unique output shaft dimension, flat key size, irregular flange hole layout and fixed pin assignment for power & encoder aviation connectors, independent custom specification different from CMU11/CMUA3 variants
3. Electrical Performance Parameters
Rated current: 43.4A(S3)/32.7A(S1), up to 300% instantaneous peak overload torque for transient cutting impact absorption
Built-in M-type multi-turn absolute encoder continuously transmits real-time speed and absolute spindle angle digital signal to driver, supporting rigid tapping, spindle orientation, constant peripheral speed turning and all core precision CNC functions
Stator winding adopts Class F international insulation grade, embedded built-in thermal sensing probes; over-temperature triggers drive power derating or safety cutoff to prevent winding burnout; built-in surge suppression circuit resists factory grid spike and surrounding inverter electromagnetic interference
Protection grade IP44 (JP44 standard), anti-dust and splash-proof for common workshop oil mist environment
4. Mechanical Structure & Application Environmental Requirement
Continuous operating ambient temperature: 0℃ ~ +40℃; storage temperature: -20℃ ~ +70℃
Working humidity: 5%~80%RH non-condensing; installation altitude over 1000m needs proper load derating due to thinner air and degraded heat dissipation
Withstands industrial vibration 10~55Hz; prohibited for sites with corrosive gas, dense oil mist and scattered conductive metal scrap to protect encoder, bearing and internal winding lifespan
5. Application Scope & Daily Maintenance Standard
Application
Maintenance Guidance
Regularly clean external cooling fan filter screen to avoid dust clogging causing poor heat dissipation and over-temperature protection stop
Periodically inspect front bearing lubrication status and aviation connector tightening to eliminate oil leakage and loose wiring induced unstable spindle rotation
For breakdown replacement, only original CMU45 dedicated encoder and matching power cable are allowed; mismatched non-standard accessories lead to feedback failure or spindle runaway fault
Refurbished spare motors complete winding high-voltage withstand test, rotating part dynamic balance correction and full-load continuous aging test per factory standards before delivery to match original performance index
Get a Quote