CACR-SR09TZ6SF-E
Description
1. Full Model Code Definition(suffix -E added)
E suffix meaning: Conform to EU industrial EMC & safety standard, optimized for European grid, partial component & PCB layout revised for overseas export market; internal core power/control specs identical to base CACR-SR09TZ6SF
2. Electrical Rating (Same base specs as standard model, E only for export certification)
Main power: 3Φ AC200~230V (-15%~+10%), 50/60Hz (EU grid compatible)
Control power: independent single-phase AC200~230V input
Continuous output:11.7A; 150% overload 60s; 300% peak overload max 3s
DC bus: DC280~320V; P/N terminals reserved for external regenerative brake resistor
3. Environmental & Mechanical
Operation temp:0℃~+55℃; Storage:-20℃~+70℃, RH5%~80% non-condensing, IP20
Max installation altitude<1000m; vertical cabinet mounting only
Net weight approx 2.3kg
4. Control & Interface
Speed adjustment ratio 1:5000, full load speed accuracy ±0.01%
CN1: Isolated digital I/O (8DI+6 relay DO, OEM fixed signal definition: servo enable, E-stop, limit, fault output etc.)
CN2: Incremental/Absolute encoder feedback port (Z customized circuit support dual encoder)
RS422 proprietary Yaskawa serial communication for parameter upload/download
Get a Quote