CIMR-VMS25P5
Description
1. Basic Overview
Model Code Definition: CIMR-VMS25P5
CIMR = Yaskawa standard inverter prefix
VMS = 626VM3S spindle special series
2 = 200V input voltage class
5P5 = Rated motor power: 5.5kW (7.5HP)
Application: CNC lathe/milling machine spindle motor high-speed drive, traditional machining center spindle control
2. Electrical Ratings
Input Specification
Output Specification
Rated applicable motor: 5.5kW
Rated output current: 33A
Output voltage: 0~AC230V
Max output frequency: 0.1Hz ~ 400Hz (spindle high-speed exclusive)
Control Mode: Closed/open loop vector control + V/F dual control, optimized for spindle low-speed high torque output
Overload Capacity
3. I/O & Communication Configuration
Digital Input: Multi-channel 24VDC sink/source selectable DI for forward/reverse run, fault reset, multi-speed switching
Analog Input: 0~10VDC / 4~20mA configurable for analog spindle speed command
Digital Output: Relay + open-collector DO for running status, fault alarm signal feedback
Communication: Built-in RS232/RS485, supports Modbus-RTU; optional Mechatrolink bus interface for CNC system linkage
Built-in brake transistor, compatible with external dynamic braking resistor for rapid spindle stop
4. Environmental & Mechanical Data
Protection Grade: IP20, cabinet wall-mounted indoor installation
Operating ambient temperature: 0℃ ~ +40℃; storage temperature: -20℃ ~ +60℃
Ambient humidity: 5%~95%RH non-condensing, no corrosive gas or conductive dust
Net weight: Approx 4kg (≈55lb)
Production Status: Original manufacturing stopped; only refurbished/used spare available for old CNC equipment maintenance
5. Core Spindle-Dedicated Functions
Wide-range high-frequency output up to 400Hz for ultra-high-speed spindle machining
Custom S-curve acceleration/deceleration curve for smooth spindle start-stop, reduce tool vibration
Complete protection: Overcurrent(OC), overvoltage(OV), undervoltage(UV), heatsink overheat, motor overload, output short-circuit & earth fault protection
JVOP-100 digital operator for parameter setup, real-time frequency display and fault code diagnosis
Get a Quote