CIMR-VCBA0002BAA
Description
1. Basic Information
Model Code Explanation: CIMR-VCBA0002BAA
CIMR: Standard Yaskawa inverter prefix
VC: V1000 series designation
BA: Single-phase AC 200~240V input specification, standard version without built-in EMC filter
0002: Capacity code
BAA: Standard control board, no optional onboard filter
Power Rating:
HD(Heavy Duty/Constant Torque): 0.25kW, rated output 1.6A
ND(Normal Duty/Variable Torque): 0.37kW, rated output 1.9A
Typical Application: Small conveyors, miniature fans, small pumps, packaging auxiliary equipment, PM & induction low-power motors
2. Electrical Parameters
Input Specification
Input: Single-phase AC 200V~240V, 50/60Hz; allowable voltage fluctuation: -15% ~ +10%安川電機e-メカサイト
3-phase Motor Output
Output voltage: 0 ~ AC230V
Output frequency range: 0.1Hz ~ 400Hz
Control Mode: V/F control + Open-loop sensorless vector control (support permanent magnet synchronous motor drive)
Overload Characteristic
HD rating: 150% rated output current for 60s; 180% for 3s
ND rating: 120% rated output current for 60s
3. I/O Configuration
Digital Input: 6-channel 24VDC sink/source selectable DI
Digital Output: 3-channel DO (1 relay output + 2 open-collector outputs)
Analog Input: 2 channels (0~10VDC / 4~20mA configurable)
Analog Output: 1-channel 0~10V/0~20mA signal output
4. Mechanical & Environmental Data
Protection Grade: IP20 (indoor cabinet wall-mounted installation)
Operating ambient temperature: -10℃ ~ +50℃; Storage temperature: -20℃ ~ +60℃
Ambient humidity: ≤95%RH non-condensing, no corrosive gas/conductive dust
Max installation altitude: 1000m without current derating; max 3000m with power derating
Dimension: W68 × H128 × D76mm; Net weight: approx 0.6kg
5. Standard Built-in Functions
Auto motor tuning, slip compensation, S-curve acceleration/deceleration setting, frequency skip function
Built-in PID constant speed/pressure control, energy-saving running mode
Multi-speed fixed frequency operation, DC injection braking for start/stop, high-flux braking
Complete protection: overcurrent, overvoltage, undervoltage, heatsink overheat, motor overload, output short & ground fault protection
Built-in RS485/Modbus-RTU communication interface; standard LED digital operator for parameter setting & fault check
Get a Quote