CIMR-PCAB2P2
Description
1. Basic Information
Model Code Definition: CIMR‑PCAB2P2
CIMR: Standard Yaskawa inverter prefix
PC = VS‑606PC3 series
A = 200V class (AC200~240V)
B = Built-in braking transistor
2P2 = Rated motor capacity 2.2kW (3HP)
Application: Fan, water pump, small conveyor, light-load asynchronous motor; single-phase input → three-phase output
Stock status: Original production discontinued; only refurbished & surplus spare stock available for equipment maintenance replacement
2. Electrical Specifications
Input Power
Rated input: Single-phase AC200~240V, 50/60Hz (also compatible with 3‑phase 200V input)
Rated input current: 20.9A
3‑Phase Motor Output
Rated output power: 2.2kW
Rated output current: 11A; Output capacity:4.2kVA
Output voltage: 0 ~ 3‑phase AC230V
Output frequency range: 0.1~400Hz
Control mode: V/F scalar control; internal DB braking circuit equipped for external braking resistor installation
Overload Specification
3. Mechanical & Ambient Data
Net weight: approx.1.3kg
Protection class: IP20, wall-mounted cabinet installation
Operating temperature: 0℃ ~ +40℃; Humidity:5%~95%RH non-condensing, no corrosive gas/dust
4. Standard Functions
Built-in brake transistor, connect external brake resistor directly for fast stop
I/O allocation: 5 digital inputs, 2 digital outputs, 1 analog input +1 analog output
Complete protection: Overcurrent, overvoltage, undervoltage, overheat, phase loss, motor overload protection
Onboard LED digital keypad for parameter setup & fault diagnosis