CIMR-PCAB1P5
June 04, 2026

CIMR-PCAB1P5

1. Basic Information Manufacturer: Yaskawa Electric Corporation, Japan Series: VS-616PC3 compact general-purpose inverter, discontinued original production Model Code Definition CIMR-PCAB1P5 PC: VS-616PC3 series; A: 200V voltage class; B: Built-in braking transistor; 1P5 = rated capacity 1.5kW Application: Small fans, water pumps, conveyor asynchronous motors, common light-duty industrial drive applications Availability: Original production stopped by manufacturer; only surplus old stock and refurbished units for maintenance replacement

Description

1. Basic Information

Manufacturer: Yaskawa Electric Corporation, Japan
Series: VS-616PC3 compact general-purpose inverter, discontinued original production
Model Code Definition CIMR-PCAB1P5
  • PC: VS-616PC3 series; A: 200V voltage class; B: Built-in braking transistor; 1P5 = rated capacity 1.5kW

    Application: Small fans, water pumps, conveyor asynchronous motors, common light-duty industrial drive applications

    Availability: Original production stopped by manufacturer; only surplus old stock and refurbished units for maintenance replacement

2. Electrical Specifications

Input Power

  • Rated input: Single-phase AC200~240V 50/60Hz, also compatible with three-phase 200V input

  • Rated input current: 12.5A

3-Phase Motor Output

  • Rated output power: 1.5kW, rated output current:7.5A

  • Output voltage range: 0 ~ 3-phase AC230V

  • Output frequency range: 0.1~400Hz

  • Control mode: V/F scalar control, internal braking transistor equipped for external braking resistor connection

Overload Rating

150% rated current for 60 seconds; 180% rated current for 3 seconds

3. Mechanical & Environmental Specifications

  • Net weight: Approx.1.1kg

  • Installation: Wall-mounted, IP20 protection grade

  • Operating ambient temperature: 0℃ ~ +40℃; ambient humidity 5%~95%RH non-condensing; indoor cabinet installation without corrosive gas or conductive dust

4. Main Functions

  1. Pre-installed braking transistor; external braking resistor can be directly wired for rapid stop control

  2. Standard configuration: 5 digital inputs, 2 digital outputs, 1 analog input & 1 analog output terminal

  3. Full protection functions: Overcurrent, overvoltage, undervoltage, overheat, phase loss and motor overload protection

  4. Equipped with digital keypad and LED display for easy parameter setting and fault checking

5. Recommended Replacement Model

Direct substitute: CIMR-VC2A0006BAA (Yaskawa V1000 series, 200V class 1.5kW inverter)


Get a Quote