ABB 3BHE019958R0101 original ABB analog measurement interface PCB
June 04, 2026

ABB 3BHE019958R0101 original ABB analog measurement interface PCB

This is original ABB analog measurement interface PCB made in Sweden for UNITROL series generator excitation system. The circuit board is coated with three-proof conformal coating to prevent damage caused by moisture, dust and corrosive gas inside control cabinet. It works as front-end signal conditioning unit between field instrument transformers and main AVR controller, processing raw AC voltage and current signals from generator side before sending standardized sampled data to master control card via backplane bus with standard rack plug-in structure.

Description

1.Product Brief Introduction

This is original ABB analog measurement interface PCB made in Sweden for UNITROL series generator excitation system. The circuit board is coated with three-proof conformal coating to prevent damage caused by moisture, dust and corrosive gas inside control cabinet. It works as front-end signal conditioning unit between field instrument transformers and main AVR controller, processing raw AC voltage and current signals from generator side before sending standardized sampled data to master control card via backplane bus with standard rack plug-in structure.

2.Model Definition Explanation

3BHE is unified fixed part prefix for ABB dedicated printed circuit spare parts of excitation and medium voltage drive equipment.
019958 is exclusive internal development serial number defined by ABB R&D department for this measurement hardware platform.
R0101 means initial official mass-production hardware revision without subsequent circuit modification, used as standard commercial delivery version.

3.Technical Specifications

Rated auxiliary supply voltage DC24V±10%, typical power consumption below 4.5W. Operating ambient temperature from -25℃ to +70℃, storage temperature -40℃~+85℃, relative humidity 5%RH~95%RH with no condensation. Signal channel isolation withstand voltage reaches 1200VAC between input acquisition circuit and internal control circuit, analog signal overall sampling precision better than ±0.2% full scale. The module is IP20 for cabinet installation and complies with IEC61000 EMC industrial anti-interference specification, net weight approximately 0.38kg.

4.Interface and Communication Configuration

Rear gold-finger backplane connector links internal rack bus to transmit processed digital sampling data and fault signals to main excitation control board. Front terminal blocks are designed for external wiring connection of voltage transformer and current transformer secondary loop. Multiple LED indicators on PCB display power supply status and input channel fault condition for on-site inspection. Only factory dedicated debug pins are reserved on board for offline calibration, no user configurable external fieldbus ports.

5.Core Functions

Receive raw alternating voltage and current signals from PT and CT installed at generator terminal, implement surge suppression, filtering and amplitude adjustment to eliminate industrial interference noise. Convert conditioned analog signals into standard digital data and upload to master AVR board for closed-loop excitation regulation calculation. Continuously execute channel self-test to detect signal loss, open circuit and short-circuit fault on input loops, lock abnormal channel output and feed fault alarm information to main controller once error is found.

6.Application Scenarios

It is assembled inside UNITROL1000 and UNITROL6000 excitation cabinets for synchronous generators of thermal power, hydropower, gas and biomass power plants. It also matches excitation control system of large synchronous driving motors used in cement rotary kiln, mine ventilation fan and petrochemical high-pressure compressor, and fits renovation project of old generator excitation control cabinet.

7.Operation and Maintenance Instructions

Disconnect cabinet total input power before disassembly or regular maintenance, keep power off over 30 minutes to discharge residual capacitance electricity and avoid static damage to precision onboard chips. Conduct quarterly maintenance to remove dust on PCB surface and gold-finger contacts with dry soft brush, tighten all external wiring terminals regularly. When system reports sampling abnormity or regulation deviation, check external transformer secondary wiring first before module replacement. Unauthorized disassembly of original components and arbitrary circuit modification are strictly forbidden, replace complete new module after permanent hardware damage is confirmed.