ABB 3BHB003041R0001(UFC719AE01) dedicated I/O interface and auxiliary power control board
June 04, 2026

ABB 3BHB003041R0001(UFC719AE01) dedicated I/O interface and auxiliary power control board

This unit is a dedicated I/O interface and auxiliary power control board matched for ABB medium voltage inverter and high-power drive system, produced in Sweden following ABB internal design specifications and IEC industrial standards. It is rack plug-in printed circuit board acting as intermediate signal conversion and power distribution component between master control unit and field I/O modules inside converter cabinet.

Description

1.Product Brief Introduction

This unit is a dedicated I/O interface and auxiliary power control board matched for ABB medium voltage inverter and high-power drive system, produced in Sweden following ABB internal design specifications and IEC industrial standards. It is rack plug-in printed circuit board acting as intermediate signal conversion and power distribution component between master control unit and field I/O modules inside converter cabinet.

2.Model Definition Explanation

3BHB stands for fixed part number prefix of ABB power electronic control board series.
003041 is exclusive internal component serial number of this interface board.
R0001 represents the first released official hardware revision version.
UFC719AE01 is the alternate functional model name defined by ABB for this hardware.

3.Technical Specifications

The board runs on cabinet inner auxiliary DC working power. Normal operating ambient temperature ranges from 0℃ to +60℃, storage temperature ranges from -40℃ to +85℃ under non-condensing humidity condition. Cabinet built-in installation protection grade is IP20. It has passed IEC61000 EMC anti-interference and industrial anti-vibration certification to adapt severe dusty and strong electromagnetic industrial site environment. It supports bidirectional processing of 4-20mA analog signal and 24V digital switching signal, with independent channel isolation design for anti-cross interference.

4.Interface and Communication Configuration

Rear golden finger connects with system backplane to acquire input power and transmit data via proprietary internal drive bus. Front terminal wiring ports are reserved for external I/O signal wiring and auxiliary power output. No independent Ethernet port is equipped, and it realizes upper data interaction relying on cabinet internal dedicated bus protocol only.

5.Core Functions

It receives control instructions and parameter data from main control board via backplane bus, completes signal isolation and format conversion for field analog and digital signals collected from peripheral sensors and execution components, then uploads processed valid data to upper controller. Meanwhile it provides stable auxiliary power supply for nearby local I/O modules, collects module abnormal overcurrent and short-circuit fault signals and feeds back alarm information to mainboard to trigger corresponding protection logic.

6.Application Scenarios

It is fixedly installed inside cabinet of ABB high and medium voltage frequency converter sets, widely used in thermal power boiler induced draft fan and water pump variable speed control, metallurgical rolling mill transmission drive, cement kiln main dragging system and mine heavy-duty belt conveyor frequency control projects.

7.Operation and Maintenance Instructions

Fully cut off cabinet main AC input power and all auxiliary DC power before disassembly or replacement, insert the circuit board into specified rack slot and lock fixing buckles tightly. Complete field wiring strictly complying with terminal definition to avoid wrong wiring causing board burnout. Carry out quarterly routine inspection and half-year comprehensive maintenance, remove accumulated dust on circuit surface and connectors with dry soft brush, never use liquid cleaning agents. Replace complete board once persistent signal failure or abnormal power output occurs after excluding peripheral wiring faults, private disassembly and onboard circuit modification are prohibited.


Get a Quote