ABB 1TNE968903R0100
June 04, 2026

ABB 1TNE968903R0100

This component is an original ABB S500 series analog input module coded AI561, designed to match AC500 and AC500-eCo PLC automation systems. It is manufactured according to IEC industrial specifications and ABB global production standards with compact DIN rail installation structure. The module focuses on collecting standard industrial analog signals from field transmitters and converting analog signals into digital data for PLC processing, featuring high measuring precision and strong anti-electromagnetic interference performance.

Description

1.Product Brief Introduction

This component is an original ABB S500 series analog input module coded AI561, designed to match AC500 and AC500-eCo PLC automation systems. It is manufactured according to IEC industrial specifications and ABB global production standards with compact DIN rail installation structure. The module focuses on collecting standard industrial analog signals from field transmitters and converting analog signals into digital data for PLC processing, featuring high measuring precision and strong anti-electromagnetic interference performance.

2.Model Definition Explanation

1TNE is the unified coding prefix for ABB low voltage automation spare parts used for global order management and product classification.
9689 is internal catalog grouping code representing S500 series PLC I/O module product family.
03 stands for third revised base hardware version different from former 01 and 02 version specifications.
R indicates factory pre-calibrated and fully tested standard finished configuration following ABB internal component coding regulations.
0100 is exclusive configuration code corresponding to AI561 fixed analog input channel definition, differing from other analog modules with varied channel types.

3.Technical Specifications

Rated working supply voltage is DC24V, total module power consumption is less than 3.2W. It is equipped with 8-channel analog input supporting standard 4-20mA current and 0-10V voltage industrial signals with 12-bit conversion resolution. Operating ambient temperature ranges from -25℃ to +60℃, storage temperature covers -40℃ to +85℃, protection grade is IP20 for cabinet inner installation. The module complies with IEC61000 EMC anti-interference standard and is equipped with channel state indicator LED.

4.Interface and Communication Configuration

Rear side adopts dedicated backplane plug-in bus connector to connect with S500 base rack, realizing high-speed data exchange with PLC CPU via internal rack bus without independent external communication wiring. Front panel is fitted with pluggable spring terminal block for field transmitter wiring. All data transmission relies on system internal backplane bus, Modbus or Profinet fieldbus functions are realized by supporting matched system communication adapter, no independent external fieldbus port is arranged on module body.

5.Core Functions

Core function is real-time acquisition of field analog signals including temperature, pressure, flow and liquid level from various site transmitters, converting analog electrical signals into digital values and uploading data to PLC main controller through backplane bus for closed-loop calculation and parameter adjustment. The module automatically detects abnormal input such as overrange or open-circuit wiring and feeds channel fault information back to upper PLC for fault warning.

6.Application Scenarios

It is widely installed inside PLC control cabinets of water treatment projects, chemical auxiliary control, packaging equipment, HVAC constant temperature control and environmental monitoring systems, used for analog parameter collection and process closed-loop regulation of industrial production sites.

7.Operation and Maintenance Instructions

Check backplane plug and front terminal block for damage or deformation before installation, confirm DC24V power supply polarity to avoid burnout from reverse connection. Fasten module onto standard 35mm DIN rail and insert into specified base slot, complete field wiring strictly according to channel identification marking. Perform semi-annual regular maintenance, remove dust on module shell and terminals with dry soft brush and forbid liquid cleaning reagents. Replace the whole module when persistent channel error occurs after excluding external circuit faults, unauthorized disassembly and internal circuit alteration are forbidden.


Get a Quote