ABB 1TNE968902R2202 DO571 relay-type digital output module
June 04, 2026

ABB 1TNE968902R2202 DO571 relay-type digital output module

This item is DO571 relay-type digital output module belonging to ABB S500-eCo I/O series, compatible with AC500 and AC500-eCo PLC control systems, produced according to IEC industrial electrical standard and ABB global manufacturing specification with compact DIN rail installation structure. It adopts mechanical relay output design to drive both AC and DC field loads, featuring wide applicable voltage range, outstanding anti-interference performance and stable backplane bus connection for cabinet installation in various industrial automatic control sites.

Description

1.Product Brief Introduction

This item is DO571 relay-type digital output module belonging to ABB S500-eCo I/O series, compatible with AC500 and AC500-eCo PLC control systems, produced according to IEC industrial electrical standard and ABB global manufacturing specification with compact DIN rail installation structure. It adopts mechanical relay output design to drive both AC and DC field loads, featuring wide applicable voltage range, outstanding anti-interference performance and stable backplane bus connection for cabinet installation in various industrial automatic control sites.

2.Model Definition Explanation

1TNE is unified part number prefix for ABB low voltage automation spare parts for global ordering and product classification management.
9689 represents internal catalog grouping code for S500 series PLC I/O module product line.
02 stands for optimized hardware base version different from initial specification.
R indicates standard finished product with full factory pre-test per ABB internal component coding rule.
2202 is exclusive configuration code corresponding to DO571 8-channel relay output specification, differentiated from DO561(2201) transistor output by internal relay circuit design and load parameter.

3.Technical Specifications

Rated working supply voltage DC24V, typical module power consumption 1.2W. Equipped with 8-channel mechanical relay digital output; single channel rated load 2A, supporting DC24V, AC24V or 100~240VAC external loads. Operating ambient temperature range 0℃~+60℃, storage temperature -40℃~+70℃, protection grade IP20 for inner cabinet mounting, isolation voltage 1500V AC between internal circuit and output contact. Mechanical service life exceeds 100000 switching operations, maximum mechanical switching frequency 10Hz, passed IEC61000 EMC certification, each channel fitted with status indicator LED.

4.Interface and Communication Configuration

Rear side is equipped with dedicated backplane plug-in bus connector, inserted into S500 base rack to realize high-speed data exchange with PLC CPU via internal rack bus without independent external communication wiring. Front panel adopts pluggable 11-pin HE10 terminal connector for external wiring of contactor coils, alternating current solenoid valves and indicator lights. All data transmission relies on system internal backplane bus; Profinet or Modbus communication expansion needs matched system communication adapter, no independent fieldbus port reserved on module shell.

5.Core Functions

Receive control instruction signal from PLC main controller through backplane bus, drive internal mechanical relay pull-in or break-off to switch on/off external AC/DC loads. The module monitors abnormal conditions including overload and short-circuit of external output loop in real time, uploading channel fault information to upper PLC system for alarm prompt and on-site troubleshooting, supporting flexible on-off control of alternating current executing components unavailable for transistor-type output modules.

6.Application Scenarios

Commonly installed inside PLC control cabinets of water treatment automation, packaging equipment, logistics conveyor lines, fan and pump centralized control and small-scale power distribution automation projects. Mainly used for AC contactor coil control, AC solenoid valve switching and high voltage indicator lamp driving in discrete industrial automation occasions where alternating current load control is required.

7.Operation and Maintenance Instructions

Inspect backplane plug and front plug terminal for crack or deformation before installation, confirm DC24V power wiring polarity to avoid module burnout caused by reverse connection. Fasten module on standard 35mm DIN rail and insert into specified base slot, complete field wiring strictly following channel marking definition. Conduct semi-annual regular maintenance, clear dust on module shell and terminals with dry soft brush and forbid liquid cleaning solvent. Replace the whole module once continuous channel fault exists after eliminating external circuit failure, unauthorized disassembly and modification of internal relay circuit are prohibited.


Get a Quote