ABB 1TGE120021R0110 upgraded MControl intelligent motor and feeder protection controller
1TGE120021R0110 is upgraded MControl intelligent motor and feeder protection controller belonging to ABB MNS iS withdrawable low voltage switchgear series, optimized with dual communication configuration compared with standard R0010 version. It integrates electrical measurement, multi-type motor protection, local interlock logic and dual-bus communication function, installed inside drawer-type motor starter cabinets for intelligent monitoring and protection of low-voltage motors and power feeders, widely used for new cabinet assembly and field spare replacement in process industry power distribution systems.
Description
Product Introduction
1TGE120021R0110 is upgraded MControl intelligent motor and feeder protection controller belonging to ABB MNS iS withdrawable low voltage switchgear series, optimized with dual communication configuration compared with standard R0010 version. It integrates electrical measurement, multi-type motor protection, local interlock logic and dual-bus communication function, installed inside drawer-type motor starter cabinets for intelligent monitoring and protection of low-voltage motors and power feeders, widely used for new cabinet assembly and field spare replacement in process industry power distribution systems.
Model Definition
1TGE is fixed coding prefix for ABB MNS iS series intelligent control modules. 120021 stands for core hardware specification of enhanced MControl feeder control unit. Suffix R0110 represents factory customized firmware edition with dual communication interface preconfigured, supporting simultaneous PROFIBUS DP and Modbus communication without later program modification.
Technical Specifications
Auxiliary control input power AC110V~AC230V, matching external current transformer with measuring current range 0.1A~630A. Operating ambient temperature ranges from -20℃ to +60℃, storage temperature -40℃~+85℃, applicable environment humidity 5%~95% without condensation. Protection grade IP20 for internal cabinet installation, mechanical size matched with standard MNS iS drawer structure, compliant with IEC and CE low voltage equipment certification standards. Front-mounted LED indicators display power supply, running status and various fault alarm codes, built-in electronic protection circuit for overload, phase loss, unbalanced current and short-circuit protection.
Interface and Communication Configuration
Bottom detachable screw terminal blocks for CT signal wiring, control power access and auxiliary switch signal connection. Equipped with onboard PROFIBUS DP and Modbus RTU dual fieldbus interfaces simultaneously, realizing dual-channel communication with upper PLC or DCS system. No independent Ethernet port reserved, remote parameter calibration, real-time data reading and remote control command transmission can be finished via either of the two communication buses according to on-site system configuration.
Core Functions
Real-time collection of three-phase working current of controlled loads to complete power parameter monitoring and load statistics. Execute full-range electronic protection including overload, phase failure, three-phase current unbalance and short-circuit trip protection to prevent motor burnout caused by abnormal power supply. Complete independent local interlock logic without upper controller participation, upload operation data, fault record and switch status through dual communication channels, receive remote start-stop instructions issued from central control room. Dual-bus redundant communication improves system data transmission stability against single bus failure.
Application Scenarios
Installed inside MNS iS low voltage drawer cabinets of petrochemical, thermal power, metallurgy and municipal wastewater treatment industries, used for intelligent control of water pumps, draught fans, compressors and conveyor motors. Specially applicable for old plant reconstruction projects requiring dual-bus communication docking between new and old different-brand control systems.
Operation and Maintenance Instructions
Cut off main circuit power and auxiliary control power before pulling out module or modifying wiring, wait for internal residual voltage full discharge. Conduct routine maintenance every three months, clear dust on module surface and wiring terminals with dry compressed air and retighten loose terminal screws regularly. In case of accidental protection tripping, first check motor winding insulation and peripheral circuit faults, inspect communication bus wiring status when data transmission interruption occurs before module replacement.