Product Introduction TC-CCR014 is a dedicated ControlNet bus interface module for C200/C300 controllers. It enables communication between the controllers and remote CIOM I/O racks across racks, and builds a ControlNet redundant control network. It is the core communication card for rack interconnection in the PKS system, and is compatible with the backplane installation of the entire Series C controller series.

Description

Model Explanation

TC = Series I/O Card of C series; CCR = ControlNet Redundant Communication; 014 = Hardware Version Number, Original Equipment Part Number 97197975-A01. Technical Specifications

Power Supply: The 24VDC power is taken from the controller rack, with a maximum power consumption of 4.2W;

Communication Rate: The ControlNet standard has a 5Mbps bus rate;

Interfaces: A single-channel coaxial ControlNet interface + internal bus of the backplane;

Isolation: Electrical isolation of the communication side from the backplane at 1500VAC;

Operating Environment: -20℃ to +70℃, humidity 5% to 90% without condensation; net weight approximately 380g; UL and CE industrial certifications.

Interface and Communication Configuration

Panel: Three-color LED indicators for operation, fault, and bus communication status;

Backplane: European-style gold finger plug-in C200/C300 local rack backplane, interacting with controller data through the internal system bus;

External: BNC coaxial terminals for connecting ControlNet bus cables, connecting each remote CIOM rack in series;

Networking: Single-card networking, paired configuration to achieve ControlNet dual-network redundant architecture.

Core Functions

ControlNet data transfer between the controller and the remote CIOM I/O rack;

Bus fault diagnosis, short circuit and open circuit alarm uploaded to the controller;

Automatic switching of redundant links in case of bus link failure to ensure uninterrupted I/O;

Support for hot plugging of racks while powered on, and automatic synchronization of configuration after replacement. Applicable scenarios

Petrochemical refining and chemical production PKS remote I/O cabinet networking, power plant boiler DCS remote I/O expansion, coal chemical plant multi-rack distributed I/O system.

Operation and maintenance instructions

Select dedicated ControlNet shielded coaxial cable for coaxial cables, tighten BNC connectors; add 75Ω terminal resistors at both ends of the bus terminal; prohibit hot-plugging of coaxial BNC connections; conduct annual inspection of bus attenuation value.


Get a Quote