SGDA-02BS
Description
1. Product Overview
2. Electrical Rating
Power Input
Input: Single-phase AC 100~115V, 50/60Hz, rated input current: 8.0A
Control circuit shares main power supply (no separate control power terminal)
Output Spec
Rated output power: 200W (0.27HP)
Continuous output current: 2.7Arms; peak overload current:8.7A (300% short-duration overload capacity)
Max three-phase output voltage: AC 0~115V
3. Control Interface (Core Feature: Analog Only, No Pulse Position Command)
CN1 control terminal receives 0~±10VDC analog voltage command for speed reference or torque setting; no differential/open-collector pulse input circuit, cannot perform pulse-type position control (distinguished from SGDA-02BP position model).
Speed control range: 1:5000; default factory setting = speed control mode, switch to torque control via internal parameter modification for tension/winding application.
Standard digital I/O terminals: Servo ON enable, external fault reset, forward/reverse JOG input, alarm relay contact output, zero-speed detection output.
RS232 serial port onboard for SigmaWin software parameter upload/download & running status monitoring; no fieldbus communication function.
Compatible with incremental encoder and battery-backed absolute encoder feedback.
4. Built-in Protection Functions
5. Environmental & Mechanical Parameters
Protection Grade: IP20, cabinet indoor installation only (no water/oil mist allowed)
Operating ambient temperature: 0℃ ~ +55℃ (non-condensing); storage temp: -20℃ ~ +85℃
Operating humidity:10%~90%RH, no dew formation
Cooling method: Natural convection air cooling, no built-in cooling fan; install via DIN rail or cabinet screw mounting
Net weight: approx 1.16kg; certified CE & UL safety standard
6. Main Functions
Front-panel independent JOG inching operation for manual motor forward/reverse test without external controller connection.
Auto inertia identification & auto gain tuning for speed loop optimization to simplify on-site commissioning.
Built-in dynamic braking circuit for rapid stop during emergency stop or sudden power loss to avoid mechanical overrun.
Internal memory stores historical fault codes for equipment troubleshooting.
7. Application & Replacement Note
Cannot directly interchange with SGDA-02BP (BP = pulse position control); direct replacement will cause machine malfunction for positioning equipment.
Typical usage: small winding machines, constant-speed feeding rollers, pay-off tension control, precision analog speed regulation automation equipment.
Get a Quote