SGDA-01BS
Description
1. Product Overview
BS = Analog Speed/Torque control model; BP = Digital pulse position control model.
2. Electrical Specifications
Power Ratings
Main input: Single-phase AC100~115V, 50/60Hz, rated input current:4.5A; control circuit shares main power supply without independent auxiliary power source
Rated continuous output current:2.2Arms; peak overload current:7.1A (300% short-time overload capacity)
Max three-phase output voltage:AC115V; rated output power:100W(0.13HP)
Control Interface (Key difference from SGDA-01BP)
CN1 control terminal receives 0~±10VDC analog voltage command for speed or torque setting; no differential/open-collector pulse input circuit, cannot receive pulse position instruction.
Speed control range:1:5000; built-in analog gain adjustment for speed loop; torque limit configurable via parameter or external analog signal.
Standard digital I/O: Servo enable, external fault reset, alarm relay output, JOG forward/reverse, zero-speed detection signal output.
Reserved RS232 serial port for SigmaWin software parameter uploading/downloading and real-time running status monitoring; no fieldbus communication function.
Compatible with incremental encoder and battery-backed absolute encoder feedback, same as BP model.
Full Protection Functions
3. Environmental & Mechanical Data
Protection class:IP20, must install inside sealed electrical cabinet, forbidden splash water, heavy oil mist and conductive dust
Operating ambient temperature:0℃ ~ +55℃ (non-condensation); storage temperature:-20℃ ~ +85℃
Allowable humidity:10%~90%RH without dew formation
Cooling method:natural air convection cooling, no built-in cooling fan; DIN rail or screw direct mounting available
Net weight:approx 0.8kg; CE & UL safety certified
4. Core Functional Features
Factory default mode: analog speed control; switchable to torque control mode by modifying internal parameters for tension/winding application.
Auto inertia identification & auto gain tuning optimizes speed-loop gain automatically to shorten field commissioning cycle.
Front-panel independent JOG inching function for manual forward/reverse motor test without external controller connection.
Built-in dynamic brake circuit for rapid motor stopping during emergency stop or sudden power cut to avoid mechanical inertial sliding.
Historical fault code storage in onboard memory for quick troubleshooting during equipment maintenance.
5. Application & Replacement Notice
Cannot directly replace SGDA-01BP (BP is pulse position control, BS is analog speed/torque only); direct swap leads to equipment failure for positioning equipment.
Typical application: small winding machines, feeding roller constant-speed drive, tension pay-off equipment, laboratory precision analog speed test bench.
Get a Quote