JZNC-OP15
Description
1. General Introduction
2. Electrical Specifications
Rated power input: AC100V ±10%, 50/60Hz, supplied from machine internal control cabinet power source
Total rated power consumption: approx 72W under full-load operation
Display configuration: built-in compact monochrome green CRT display module driven by onboard JSP04-1 circuit board
Signal interface: dual dedicated pin connectors at rear housing for NC bus communication and power wiring
Net weight: around 2.4~2.6kg; overall dimension: 223mm × 200mm × 35mm
3. Front Panel Layout & Key Distribution
Mode selection keys: AUTO, MDI, JOG, ZRN, DRY RUN, SINGLE BLOCK working mode switch
Program edit keys: numeric input, address code (G/M/S/T), insert/delete/modify for NC program editing
Manual operation keys: each axis jog direction keys, feedrate override & spindle speed adjustment knobs
Auxiliary function keys: coolant control, spindle start/stop, machine lock and diagnostic shortcut keys
4. Core Functional Description
NC Program Management: input, edit, store and call part machining NC programs directly through front keypad
Axis Manual Control: JOG incremental movement, mechanical zero return and workpiece alignment for all feed axes
Parameter Setup: view, modify and save system servo parameters, machine coordinate offset and tool compensation data
Real-time Monitoring: real-time display of actual axis position, spindle running speed, servo drive status and I/O signal state on CRT screen
Fault Diagnosis: automatically pop up alarm codes and failure prompts once servo, spindle or peripheral circuit malfunction occurs for troubleshooting
5. Ambient Working Conditions
Operating temperature range: 0℃ ~ +50℃; storage ambient temperature: -20℃ ~ +70℃
Working humidity: 10%~85%RH without condensation; install inside sealed operation cabinet away from cutting fluid splash, oil mist, corrosive gas and strong electromagnetic interference from high-power equipment
Vibration restriction: avoid continuous mechanical shock and intense vibration during machine running
6. Disassembly & Replacement Procedure
Cut off total machine main power supply fully, wait minimum 5 minutes for internal CRT high-voltage capacitor complete discharge to prevent electric shock hazard
Mark definition of every rear connecting cable sequentially before unplugging power and signal wiring terminals
Remove surrounding fixing mounting screws and pull out JZNC-OP15 unit from embedded cabinet installation slot
Mount new replacement panel into original installation position and fasten fixing screws securely
Recover all wiring strictly following pre-marked terminal definition; power on machine after wiring completion and test display & all key functions before formal trial machining
7. Common Fault Troubleshooting
CRT no display after power-up: check AC100V input voltage, panel internal power fuse integrity and loose solder on built-in JANCD-JSP04-1 board
Individual keys no response: inspect damaged membrane switch contact or broken internal keypad wiring
Entire panel out of communication with CNC host: check open circuit or poor contact of main rear communication multi-core cable
8. Safety Instructions
Forbid unauthorized disassembly of internal CRT high-voltage components and arbitrary modification of original internal circuit wiring; residual high voltage exists inside display module long after power cut-off
All internal maintenance work must be completed by professional technicians familiar with Yasnac J300 CNC system hardware structure
Always disconnect machine main power before any panel inspection or component replacement operation