JANCD-XTU01B
June 02, 2026

JANCD-XTU01B

JANCD-XTU01B is the external axis / auxiliary motion control PCB for Motoman XRC1000 / XRC2001 robot controllers. It controls additional servo axes (e.g., positioners, linear slides) synchronized with the robot.

Description

1. Basic Information

  • Model: JANCD-XTU01B (Rev E common)

  • Manufacturer: Yaskawa Electric (Motoman Robotics)

  • Applicable Controller: XRC1000 / XRC2001 (XRC series only)

  • Function: External axis control board (up to 2–3 auxiliary axes)

  • Status: Discontinued (Obsolete); only used / refurbished available

  • System Match: Works with XCP02B (CPU), XMM01/XMM02 (memory), XSL02 (conveyor tracking)

2. Key Specifications

  • Power: 5 VDC (from XRC backplane), ~200 mA

  • Operating Temp: 0 °C to +55 °C (non-condensing)

  • Humidity: 5%–95% RH, non-condensing

  • Communication: RS-232 / RS-485 to servo amplifiers; internal bus to XCP02B

  • Axis Control: Up to 3 external servo axes (position / speed / torque)

  • Encoder: Supports incremental (A/B/Z) and absolute serial encoders

  • Dimensions: ~100×160×20 mm

  • Weight: ~150 g

3. Core Functions

  • External Axis Control: Drives auxiliary servo motors (positioners, turntables, linear units).

  • Synchronization: Coordinates motion with robot for welding, cutting, and handling.

  • Closed-Loop Control: Current / speed / position loops for high accuracy.

  • I/O Interface: Digital inputs (home, limit) and outputs (enable, alarm) for external devices.

  • Safety: Overcurrent, overvoltage, overtemperature protection.

4. Compatibility & Installation

  • Only for XRC: Not compatible with DX100 / DX200 / FS100.

  • Slot Location: Installs in dedicated XRC cabinet slot, connects to XCP02B via internal bus.

  • Wiring: Servo encoder and power cables to external amplifiers; I/O to field sensors.

5. Common Alarms & Issues

  • Alarm 4201: External axis communication loss (XTU01B or cable fault).

  • Alarm 4202: Overcurrent on external axis (wiring short or amplifier fault).

  • No axis movement: 5 VDC power fault or enable signal missing.

  • Position drift: Encoder cable damage or XTU01B signal circuit degradation.

6. Maintenance & Replacement

  • ESD Protection: Use anti-static wristband.

  • Power Off: Disconnect controller power and wait 5 minutes before handling.

  • Refurbished Warranty: Typically 3–6 months.


Get a Quote