JANCD-X1002
June 02, 2026

JANCD-X1002

Model: JANCD-X1002 Manufacturer: Yaskawa Electric Corporation (Motoman Robotics) Applicable Controller: DX100 Robot Controller (mainstream for 6‑axis robots) Function: High‑speed digital I/O (sensor/actuator) Motion control signal interface External axis synchronization Safety interlock & E‑stop logic Revision: REV.A / REV.B (drop‑in compatible)

Description

1. General Information

  • Model: JANCD-X1002

  • Manufacturer: Yaskawa Electric Corporation (Motoman Robotics)

  • Applicable Controller: DX100 Robot Controller (mainstream for 6‑axis robots)

  • Function:

    • High‑speed digital I/O (sensor/actuator)

    • Motion control signal interface

    • External axis synchronization

    • Safety interlock & E‑stop logic

  • Revision: REV.A / REV.B (drop‑in compatible)

2. Specifications

2.1 Electrical

  • Supply Voltage: 24 VDC ±10%

  • Current Consumption: ≤ 1.2 A

  • Fuse: 1 × 3 A (fast‑blow, on‑board)

  • Inputs: 32 × 24 VDC (NPN/PNP auto‑sense)

  • Outputs: 16 × 24 VDC / 0.5 A (transistor, PNP)

  • Isolation: Opto‑isolated (2500 Vrms)

2.2 Physical

  • Dimensions: 190 mm × 120 mm × 35 mm

  • Weight: Approx. 150 g

  • Mounting: DX100 optional slot (4 × M3 screws, 0.8–1.0 N·m)

2.3 Environmental

  • Operating Temp: 0 °C to +55 °C

  • Storage Temp: −10 °C to +60 °C

  • Humidity: 5%–80% RH, non‑condensing

  • Vibration: ≤ 0.5 G (10–500 Hz)

3. Connectors (CN1–CN4)

  • CN1: 24 VDC Power
    1: +24 VDC
    2: 0 VDC (GND)
    3: FG (Frame Ground)
  • CN2: Digital Inputs (IN01–IN32)
    • IN01–IN16: Group 1 (common GND)

    • IN17–IN32: Group 2 (common GND)

  • CN3: Digital Outputs (OUT01–OUT16)
    • OUT01–OUT08: Group 1 (common +24 V)

    • OUT09–OUT16: Group 2 (common +24 V)

  • CN4: Safety & Sync
    1: E‑stop IN (NC)
    2: E‑stop GND
    3: Sync IN (external encoder)
    4: Sync OUT (to external axis)

4. LED Indicators

  • PWR (Green): On = 24 VDC normal

  • RUN (Green): Blinking = board active; Off = fault

  • ALM (Red): On = fuse blown / E‑stop open / overcurrent

  • COM (Yellow): Blinking = I/O communication active

5. Installation

  1. Power OFF controller; wait 5 min for capacitor discharge.

  2. Use anti‑static wristband.

  3. Insert board into DX100 slot; secure with 4 × M3 screws.

  4. Connect CN1–CN4 per wiring diagram.

  5. Power ON; verify:

    • PWR = On

    • RUN = Blinking

    • ALM = Off

6. Safety Features

  • Overcurrent protection: 3 A fuse

  • E‑stop interlock: Safety Category 3

  • Opto‑isolation: Prevents ground loops

  • Fault feedback: ALM signal to DX100

7. Maintenance & Troubleshooting

7.1 Maintenance

  • Quarterly: Check connectors & fuse.

  • Annually: Clean dust (low‑pressure air); inspect solder joints.

7.2 Troubleshooting

  • PWR Off: Check 24 VDC at CN1; verify wiring.

  • ALM On: Check 3 A fuse; test E‑stop continuity.

  • RUN Off: Re‑seat board; check for short circuits.

  • I/O No Response: Verify CN2/CN3 wiring; check LED status.

8. Compatibility

  • Replaces: JANCD-X002, JANCD-X001 (older I/O boards)

  • Compatible with: DX100 standard/extended I/O

  • Applications: Welding, handling, assembly, palletizing

9. Ordering Information

  • Part Number: JANCD-X1002 (specify revision: REV.A/REV.B)

  • Manufacturer: Yaskawa Electric Corporation

  • Warranty: 12 months (normal operation)

10. Warnings

  • For qualified personnel only.

  • Disconnect power before servicing; wait for discharge.

  • Do not modify board; use correct fuse rating (fire/equipment risk).

  • Yaskawa not liable for improper use/installation.


Get a Quote