JANCD-TUOI
June 02, 2026

JANCD-TUOI

Model: JANCD-TU01 Manufacturer: Yaskawa Electric (Motoman Robotics) Applicable Controllers: Motoman XRC / ERC robot controllers Function: Main power ON/OFF, contactor control, E-stop interlock, auxiliary power distribution Revision: REV.A / REV.B (compatible with TU02/TU05 in same cabinet)

Description

1. General Information

  • Model: JANCD-TU01 (misspelled: JANCD-TUOI)

  • Manufacturer: Yaskawa Electric (Motoman Robotics)

  • Applicable Controllers: Motoman XRC / ERC robot controllers

  • Function: Main power ON/OFF, contactor control, E-stop interlock, auxiliary power distribution

  • Revision: REV.A / REV.B (compatible with TU02/TU05 in same cabinet)

2. Specifications

2.1 Electrical

  • Supply Voltage: 24 VDC ±10%

  • Fuses: 2 × 3 A fast-blow (control circuits)

  • Relay Rating: 24 VDC / 5 A (resistive)

  • Control Signals: E-stop interlock, main contactor coil, power enable

2.2 Physical

  • Dimensions: 110 mm × 95 mm × 25 mm

  • Weight: ~90 g

  • Mounting: Standard XRC/ERC slot; 4 × M3 screws (0.8–1.0 N·m)

2.3 Environmental

  • Operating Temp: 0 °C to +40 °C

  • Storage Temp: −10 °C to +60 °C

  • Humidity: 5%–80% RH (non-condensing)

  • Vibration: ≤ 0.5 G (10–500 Hz)

3. Connectors & Pinout

  • CN1: 24 VDC Power & Control In

    1: +24 VDC

    2: 0 VDC (GND)

    3: Main ON (CPU signal)

  • CN2: Main Contactor Output

    1: Coil +

    2: Coil −

  • CN3: E-stop / Safety Interlock

    1: E-stop IN

    2: E-stop GND

  • CN4: Auxiliary 24 VDC Out

    1: Switched +24 VDC

    2: 0 VDC

4. LED Indicators

  • PWR (Green): 24 VDC supply OK

  • ON (Green): Main contactor energized

  • ALM (Red): Fault (fuse blown, E-stop open, relay/coil error)

5. Installation

  1. Power OFF controller; wait 5 min for capacitor discharge.

  2. Use anti-static wristband.

  3. Insert TU01 into cabinet slot; secure with 4 × M3 screws.

  4. Connect CN1–CN4 per cabinet diagram.

  5. Power ON; verify PWR=ON, ON=ON, ALM=OFF.

6. Safety

  • Dual 3 A fuses: Overcurrent protection

  • E-stop interlock: Safety Category 3 compliant

  • Relay isolation: Control/power circuit separation

  • ALM fault signal: Sent to controller for logging

7. Maintenance & Troubleshooting

7.1 Maintenance

  • Quarterly: Check connectors & fuses.

  • Annually: Clean dust (low-pressure air); inspect relay contacts.

7.2 Troubleshooting

  • PWR OFF: Check 24 VDC at CN1; verify wiring/connector.

  • ALM ON: Check 3 A fuses; test E-stop continuity; inspect relay/coil.

  • ON OFF (PWR ON): Check contactor coil resistance; verify CN2 voltage.

  • Intermittent: Inspect pins for corrosion/bending; check contacts for pitting.

8. Compatibility

  • Replaces: JANCD-TU02 (older), JANCD-TU02B

  • Compatible with: JANCD-TU05 (same cabinet, different revision)

  • Applications: Welding, material handling, assembly robots

9. Ordering

  • Part Number: JANCD-TU01 (specify revision: REV.A/REV.B)

  • Manufacturer: Yaskawa Electric Corporation

  • Warranty: 12 months (normal operation)

10. Warnings

  • For qualified personnel only.

  • Disconnect power before servicing; wait for discharge.

  • Do not modify board; use correct fuse rating (fire/equipment risk).

  • Yaskawa not liable for improper use/installation.