JANCD-TUO5
Description
1. General Information
Model: JANCD-TU05 (common misspelling: JANCD-TUO5)
Manufacturer: Yaskawa Electric Corporation (Motoman Robotics)
Applicable Controllers: Motoman XRC / ERC series robot controllers
Function: Main power ON/OFF control, main contactor drive, emergency stop (E-stop) interlock, auxiliary power sequencing
Core Relay: Omron LY2, 24 VDC coil
Revisions: REV.A, REV.B, REV.C0 (C0 is latest, fully compatible with older revisions)
2. Specifications
2.1 Electrical
Supply Voltage: 24 VDC ±10%
Fuses: 2 × 5 A fast-blow (primary/secondary circuits)
Relay Contact Rating: 24 VDC / 5 A (resistive load)
Control Signals: E-stop interlock, main contactor coil, auxiliary power enable
2.2 Physical
Dimensions: 120 mm × 100 mm × 30 mm
Weight: Approx. 100 g
Mounting: Standard slot in XRC/ERC cabinet; 4 × M3 screws (torque 0.8–1.0 N·m)
2.3 Environmental
Operating Temperature: 0 °C to +40 °C
Storage Temperature: −10 °C to +60 °C
Humidity: 5%–80% RH, non-condensing
Vibration: ≤ 0.5 G (10–500 Hz)
Altitude: ≤ 1,000 m above sea level
3. Connectors & Pin Assignment
CN1: 24 VDC Power + Control Input
Pin 1: +24 VDC
Pin 2: 0 VDC (GND)
Pin 3: Main ON signal (from CPU)
CN2: Main Contactor Output
Pin 1: Contactor coil +
Pin 2: Contactor coil −
CN3: E-stop / Safety Interlock Input
Pin 1: E-stop IN
Pin 2: E-stop GND
CN4: Auxiliary Power Output
Pin 1: +24 VDC (switched)
Pin 2: 0 VDC
4. LED Indicators
PWR (Green): ON when 24 VDC supply is normal
ON (Green): ON when main contactor is energized (closed)
ALM (Red): ON if:
Fuse blown (either 5 A fuse)
E-stop circuit open
Relay coil fault
Main contactor feedback error
5. Installation Procedure
Power OFF the controller and all connected equipment.
Wait 5 minutes for internal capacitors to discharge.
Use an anti-static wristband to prevent ESD damage.
Insert JANCD-TU05 into the designated cabinet slot.
Secure with 4 × M3 screws (torque 0.8–1.0 N·m).
Connect CN1–CN4 per cabinet wiring diagram.
Power ON the controller; verify:
PWR = ON
ON = ON
ALM = OFF
6. Safety Features
Dual 5 A Fuses: Overcurrent protection for control circuits
E-stop Interlock: Complies with Safety Category 3
Relay Isolation: Electrical separation between low-voltage control and power circuits
Fault Alarm: ALM signal sent to controller for diagnostic logging
7. Maintenance & Troubleshooting
7.1 Maintenance
Quarterly: Check connector tightness and fuse condition.
Annually: Clean dust with low-pressure dry air; inspect relay contacts for wear or discoloration.
7.2 Troubleshooting
PWR OFF:
Check 24 VDC supply at CN1 pins 1–2.
Verify CN1 wiring and connector integrity.
ALM ON:
Check both 5 A fuses; replace if blown.
Test E-stop circuit continuity at CN3.
Inspect relay coil and contacts for damage.
ON OFF (PWR ON):
Check main contactor coil resistance.
Verify CN2 connections and coil voltage.
Intermittent Operation:
Inspect connector pins for corrosion or bending.
Check relay contacts for pitting or oxidation.
8. Compatibility & Replacement
Replaces: JANCD-TU02, JANCD-TU02B (wiring changes may be required)
Backward Compatible: JANCD-TU05 REV.C0 directly replaces REV.A / REV.B (no wiring changes)
Applications: Welding, material handling, assembly, general automation
9. Ordering Information
Part Number: JANCD-TU05 (specify revision if required: REV.C0)
Manufacturer: Yaskawa Electric Corporation
Warranty: 12 months under normal operating conditions
10. Warnings
For qualified technical personnel only.
Disconnect all power sources before servicing; wait for capacitor discharge.
Do not modify the board or replace fuses with incorrect ratings (fire/equipment damage risk).
Yaskawa is not liable for improper use, modification, or installation.