Model: JANCD-TU05 REV.C0 (also written as REV.CO) Manufacturer: Yaskawa Electric Corporation (Motoman Robotics), Japan Applicable Controllers: Motoman XRC / ERC series robot controllers Function: Power ON/OFF control relay board; manages main contactor, auxiliary power sequencing, and emergency stop (E-stop) interlock inside the controller cabinet Core Component: Omron LY2 relay (24 VDC)

Description

1. General Information

Model: JANCD-TU05 REV.C0 (also written as REV.CO)
Manufacturer: Yaskawa Electric Corporation (Motoman Robotics), Japan
Applicable Controllers: Motoman XRC / ERC series robot controllers
Function: Power ON/OFF control relay board; manages main contactor, auxiliary power sequencing, and emergency stop (E-stop) interlock inside the controller cabinet
Core Component: Omron LY2 relay (24 VDC)

2. Specifications

2.1 Electrical

  • Supply Voltage: 24 VDC ±10%

  • Fuses: 2 × 5 A fast-blow fuses

  • Relay Rating: 24 VDC / 5 A (resistive load)

  • Control Functions: Main contactor drive, E-stop safety interlock, auxiliary power distribution

2.2 Physical

  • Dimensions: 120 mm × 100 mm × 30 mm

  • Weight: Approx. 100 g

  • Mounting: Standard slot in XRC/ERC cabinet; 4 × M3 screws (torque: 0.8–1.0 N·m)

2.3 Environmental

  • Operating Temperature: 0 °C to +40 °C

  • Storage Temperature: −10 °C to +60 °C

  • Humidity: 5%–80% RH, non-condensing

  • Vibration: ≤ 0.5 G (10–500 Hz)

  • Altitude: ≤ 1,000 m above sea level

2.4 Compatibility

  • Replaces: JANCD-TU05 REV.A / REV.B (fully backward compatible, no wiring changes needed)

  • Applications: Welding, material handling, assembly, general automation

3. Interface & Connectors

  • CN1: 24 VDC power + control signal input (from CPU/safety circuit)

  • CN2: Main contactor coil output

  • CN3: Emergency stop / safety interlock input

  • CN4: Auxiliary power distribution output

4. LED Indicators

  • PWR (Green): ON when 24 VDC supply is normal

  • ON (Green): ON when main contactor is energized (closed)

  • ALM (Red): ON for fuse blow, E-stop circuit open, or relay coil fault

5. Installation Instructions

  1. Power OFF the controller; wait 5 minutes for internal capacitors to discharge.

  2. Wear an anti-static wristband to prevent ESD damage.

  3. Insert the board into the designated cabinet slot; secure with 4 × M3 screws.

  4. Connect CN1–CN4 per the cabinet wiring diagram.

  5. Power ON the controller; verify: PWR = ON, ON = ON, ALM = OFF.

6. Safety & Protection Features

  • Dual 5 A fuses: Overcurrent protection for control circuits

  • E-stop interlock: Complies with Safety Category 3

  • Relay isolation: Electrical separation between low-voltage control and power circuits

  • Fault alarm: ALM signal sent to controller for diagnostic logging

7. Maintenance & Troubleshooting

7.1 Maintenance Schedule

  • Quarterly: Check connector tightness and fuse condition.

  • Annually: Clean dust with low-pressure dry air; inspect relay contacts for wear.

7.2 Troubleshooting

  • PWR OFF: Check 24 VDC supply and CN1 wiring.

  • ALM ON: Check 5 A fuses, E-stop circuit continuity, and relay coil.

  • ON OFF (PWR ON): Check main contactor coil and CN2 connections.

  • Intermittent operation: Inspect connector pins and relay contacts for corrosion.

8. Ordering & Warranty

  • Part Number: JANCD-TU05 REV.C0

  • Origin: Japan

  • Warranty: 12 months under normal operating conditions

9. Warnings

  • For qualified technical personnel only.

  • Disconnect all power sources before servicing; wait for capacitor discharge.

  • Do not modify the board or replace fuses with incorrect ratings (risk of fire or equipment damage).

  • Yaskawa is not liable for improper use, modification, or installation.