JANCD-TU05
Description
1. General Description
2. Specifications
2.1 Electrical
Supply voltage:24 VDC ±10%
Fuses:2 × 5 A (fast‑blow)
Relay rating:24 VDC / 5 A (resistive)
Function:Main contactor control, auxiliary power ON/OFF, emergency stop interlock
2.2 Physical
Dimensions:120 mm × 100 mm × 30 mm
Weight:approx. 100 g
Mounting:Standard slot inside XRC/ERC cabinet, 4 × M3 screws
2.3 Environment
Operating temperature:0 °C to +40 °C
Storage temperature:−10 °C to +60 °C
Humidity:5%–80% RH, non‑condensing
Vibration:≤ 0.5 G (10–500 Hz)
Altitude:≤ 1,000 m
2.4 Compatibility
Controllers:YASNAC XRC, ERC series
Applications:Welding, material handling, assembly, general automation
3. Interface & Connectors
CN1:24 VDC power and control signal input (from CPU/safety circuit)
CN2:Main contactor coil output
CN3:Emergency stop / safety interlock input
CN4:Auxiliary power distribution output
4. LED Indicators
PWR (green):On when 24 VDC supply is normal
ON (green):On when main contactor is energized
ALM (red):On for fuse blow, safety circuit open, or relay fault
5. Installation
Power OFF the controller; wait 5 minutes for capacitor discharge.
Use anti‑static wristband.
Insert board into designated slot; secure with four M3 screws (0.8–1.0 N·m).
Connect CN1–CN4 per cabinet wiring diagram.
Power ON; verify PWR ON, ON ON, ALM OFF.
6. Safety & Protection
Dual 5 A fuses for overcurrent protection
Emergency stop interlock (Category 3 compliant)
Relay‑based isolation between control and power circuits
Fuse‑blown alarm signal to controller
7. Maintenance & Troubleshooting
Quarterly:Check connector tightness and fuse condition.
Annually:Clean dust with low‑pressure dry air; inspect relay contacts.
PWR off:Check 24 VDC supply and CN1 wiring.
ALM on:Check fuses, E‑stop circuit, and relay coil.
ON not lit:Check contactor coil and CN2 connections.
8. Ordering Information
Model:JANCD‑TU05
Manufacturer:Yaskawa Electric Corporation (Motoman Robotics)
Origin:Japan
Warranty:12 months under normal operation
Get a Quote