jancd-tu02
Description
1. General Description
2. Specifications
2.1 Electrical
Supply voltage:24 VDC ±10%
Current consumption:0.35 A typical
Digital inputs:16 points(24 VDC, sink/source selectable)
Digital outputs:8 relay outputs
Rated:24 VDC / 50 mA max per point
Isolation:Photocoupler(input);relay(output)
Power consumption:≤ 8.5 W
2.2 Environment
Operating temperature:0 °C to +45 °C
Storage temperature:−10 °C to +60 °C
Humidity:5%–80% RH, non‑condensing
Vibration:≤ 0.5 G(10–500 Hz)
Altitude:≤ 1,000 m
2.3 Compatibility
Controllers:YASNAC XRC, ERC series
CPU boards:JANCD‑CP03B, JANCD‑CP04B
Application:Welding, material handling, assembly, general automation
3. Board Interface
CN1(Controller bus)
50‑pin flat cable;connects to CPU board
Carries:I/O status, safety signals, configuration data
TB1(Field terminal block)
Screw terminals for all I/O and safety
Includes:24 VDC, 0 V, input common, output common, E‑stop, limit signals
CN2(Power)
24 VDC power input for board logic
4. LED Indicators
PWR(green):On when 24 VDC is normal
IN01–IN16(green):On when input is active
OUT01–OUT08(green):On when relay output is energized
ALM(red):On for safety circuit fault or communication error
5. Installation
Power OFF controller;wait 5 minutes for capacitors to discharge.
Use anti‑static wristband.
Insert board into designated slot;fix with four M3 screws(0.8–1.0 N·m).
Connect CN1 to CPU flat cable.
Wire field devices to TB1 per terminal assignment.
Apply 24 VDC to CN2.
Power ON;check LEDs:PWR ON, ALM OFF.
6. Safety Features
Hardware emergency stop(Category 3 compliant)
Overcurrent protection on I/O
Short‑circuit detection(input/output)
Galvanic isolation between field and controller
Safety signal monitoring with alarm output
7. Maintenance & Troubleshooting
Maintenance
Quarterly:Check terminal screw tightness.
Annually:Clean dust with low‑pressure dry air;check flat cables.
Troubleshooting
PWR off:Check CN2 24 VDC supply and wiring.
ALM on:Check E‑stop circuit, limit switches, CN1 cable.
Input LED not on:Check field device and common voltage.
Output not activating:Check output common and load wiring.
8. Ordering Information
Model:JANCD‑TU02
Motoman P/N:150516‑2
Manufacturer:Yaskawa Electric Corporation(Motoman Robotics)
Origin:Japan
Warranty:12 months under normal operation