VMIVME-4140 (GE/VMIC 6U VMEbus 32‑Channel 12‑bit Analog Output Board)
Description
Model Interpretation
VMIVME: VMEbus module series (VMIC/GE)
4140: High‑density 32‑channel 12‑bit analog output board
Common suffix:
‑000: Standard industrial grade (0°C to +60°C)
Technical Parameters
Analog Output
Channels: 32 independent, each with dedicated 12‑bit DAC
Resolution: 12‑bit (0.024% FSR)
Voltage Ranges (software‑selectable):
Bipolar: ±2.5 V, ±5 V, ±10 V
Unipolar: 0–2.5 V, 0–5 V, 0–10 V
Current Drive: ±10 mA per channel (sink/source)
Output Impedance: 0.8 Ω
Update Rate: Up to 10 kHz; random (non‑scanning) or synchronous (software/external trigger) double‑buffered updates
Settling Time: 18 μs (full‑scale step, 0.01% accuracy)
Accuracy & Drift
Initial Accuracy (+25°C):
Gain error: ±0.03% of set value
Offset error: ±1.5 mV
Temperature Drift: ±35 ppm/°C (gain), ±30 μV/°C (offset)
Long‑Term Drift: ±45 ppm/1000 hours (gain)
Crosstalk: ≥70 dB (DC–1 kHz)
Bus & Mechanical
Form Factor: 6U VMEbus (233.35 × 160 mm), single‑slot
VME Interface: Slave, VME64 compliant
Power: +5 VDC ±10%, <5 W
Operating Temp: 0°C to +60°C (standard); optional –40°C to +85°C
Cooling: Passive convection
Diagnostics & Calibration
Self‑Test: On‑board diagnostics; front‑panel status LED
Calibration: Automatic via reset or software; single reference potentiometer (no manual trim per channel)
Field Disconnect: Outputs can be isolated for offline testing
Core Functions
32‑Channel Precision Analog Control: Independent 12‑bit DACs deliver high accuracy and low crosstalk for multi‑loop control.
Software‑Configurable Ranges: Unipolar/bipolar voltage and ±10 mA current drive adapt to diverse actuator/sensor needs.
Synchronous/Random Updates: Double‑buffered synchronous updates ensure channel alignment; random mode optimizes responsiveness.
Automatic Calibration & Diagnostics: Minimizes maintenance; self‑test and field disconnect simplify system checkout.
Rugged VME Integration: 6U form factor, passive cooling, and industrial temp range suit harsh environments.
Applications
Industrial Automation: DCS, PLC analog output, valve/actuator control, motion control.
Aerospace & Defense: Avionics signal simulation, radar control, test bench analog I/O.
Test & Measurement: ATE, hardware‑in‑the‑loop (HIL) simulators, sensor emulation.
Energy & Power: Turbine control, power plant analog output, grid simulation.
Usage & Maintenance
Installation: Insert into 6U VME chassis; connect front‑panel analog output connectors.
Configuration: Select voltage/current ranges and update mode via software; set VME slave address via jumpers.
Maintenance: Passive cooling requires no fan maintenance; perform annual calibration check via software command.
Status: Restricted Production Phase (RPP) since May 31, 2019; replacement is Abaco’s modern VME/VPX AO boards。
Get a Quote