SR745-W2-P5-G5-HI (GE Multilin 745 Transformer Protection Relay)
June 02, 2026

SR745-W2-P5-G5-HI (GE Multilin 745 Transformer Protection Relay)

Product Description The SR745-W2-P5-G5-HI is a high‑speed, microprocessor‑based transformer protection relay from GE Multilin’s 745 series, built for two‑winding power transformers, autotransformers, and reactors. It delivers comprehensive differential, overcurrent, thermal, and ground fault protection, plus precision metering and diagnostics for medium/high‑voltage assets.

Description

Model Interpretation

SR745: 745 series transformer protection relay

W2: 2‑winding transformer configuration

P5: 5 A CT secondary phase current input

G5: 5 A ground CT input

HI: High‑impedance control power (70–265 VAC / 90–300 VDC, 48–62 Hz)

Technical Parameters

Input & Power

CT Input: 5 A phase (2 windings); 5 A ground

VT Input: 60–120 V phase‑neutral

Control Power: 70–265 VAC / 90–300 VDC, 48–62 Hz

Power Consumption: ≤12 VA typical

Protection Functions

Differential: 2‑winding restrained differential, high‑speed (≤8 ms trip)

Overcurrent: Phase/ground, IEC inverse/definite time, 0.1–20×In

Thermal: Winding/iron core overload, RTD‑based overtemperature

Voltage/Frequency: Over/undervoltage, over/underfrequency, overexcitation blocking

Ground Fault: Restricted earth fault (REF), high‑Z ground fault

Trip Time: ≤8 ms (differential); ≤15 ms (overcurrent)

I/O & Interfaces

Analog Inputs: 4 RTD (3‑wire; Pt100, Ni100/120, Cu10)

Analog Outputs: 4 × 4–20 mA, isolated, 600 Ω burden max

Digital Inputs: 16 opto‑isolated (dry/wet, ≤1 ms)

Relay Outputs: 8 Form C (5 A / 250 VAC)

Communication: RS‑232 (front), RS‑485 (Modbus RTU), Ethernet (IEC 61850, DNP3)

Display & User Interface

Display: 40‑character backlit LCD

Indicators: 12 LED (RUN, TRIP, ALARM, FAULT, SERVICE)

Keypad: Numeric/navigation for local programming

Mechanical & Environmental

Dimensions: 228.6 mm H × 177.8 mm W × 180.9 mm D (9”×7”×7.125”)

Mounting: Panel mount (19” rack compatible)

Enclosure: Flame‑retardant plastic; IP50 (front), IP20 (overall)

Operating Temp: -40°C to +60°C

Storage Temp: -40°C to +85°C

Humidity: 5–95% non‑condensing

Certifications: UL, CE, CSA, IEC 60255, ATEX

Metering & Diagnostics

Metering: 3‑phase current/voltage, power, energy, frequency, PF, demand (0.2% accuracy)

Diagnostics: Event log (1024 events), fault recorder (256‑cycle oscillography), pre‑trip data

Thermal Modeling: RTD biasing, load loss cooling curves, hot‑spot estimation

Core Functions

High‑Speed Differential Protection: Detects internal winding faults in <10 ms to prevent catastrophic failure.

Comprehensive Thermal Protection: Monitors winding/bearing temps via RTDs and models thermal stress.

Wide‑Range HI Power: Operates from 70–265 VAC / 90–300 VDC for flexible substation integration.

Advanced Communications: Ethernet IEC 61850 for grid‑wide SCADA and Modbus for legacy systems.

Robust Fault Diagnostics: Captures oscillography and event logs for root‑cause analysis.

Applications

Power Utilities: Transmission/distribution transformers, substations

Oil & Gas: Step‑up/down transformers, offshore platforms

Metallurgy: Furnace transformers, heavy‑duty process units

Petrochemical: Refinery transformers, corrosive environments

Renewables: Wind/solar farm grid‑intertie transformers

Usage & Maintenance

Installation: Panel‑mount; wire CT/VT, HI control power, RTDs, and communications.

Programming: Use front keypad or connect to EnerVista 745 software via RS‑232/Ethernet.

Configuration: Set CT/VT ratios, differential slopes, protection curves, and RTD types.

Maintenance: Inspect terminals annually; update firmware; verify settings after system changes.