SR469-P5-HI-A20-E (GE Multilin 469 Motor Management Relay)
June 02, 2026

SR469-P5-HI-A20-E (GE Multilin 469 Motor Management Relay)

Product Description The SR469-P5-HI-A20-E is a high-performance, microprocessor-based medium‑voltage motor management relay from GE Multilin’s 469 series. It integrates comprehensive protection, precision metering, and flexible control for critical industrial motors, with an enhanced front panel for improved local visibility and operation.

Description

Model Interpretation

SR469: 469 series motor management relay (draw‑out, modular platform)

P5: 5 A CT secondary phase current input

HI: High‑impedance wide‑range control power (70–265 VAC / 90–300 VDC)

A20: 4 isolated 4–20 mA analog outputs

E: Enhanced front panel (larger LCD, no Ethernet)

Technical Parameters

Input & Power

CT Input: 5 A phase (5 channels); 2 ground CT inputs

VT Input: 0–690 V (delta/wye configurable)

Control Power: 70–265 VAC / 90–300 VDC, 48–62 Hz

Power Consumption: 5–15 W typical

Protection & Timing

Protection Functions: Overload (thermal memory), short circuit, ground fault, stall, undervoltage/overvoltage, phase loss/reversal, RTD overtemperature

Overcurrent Curves: IEC 60255‑3 inverse / definite time, 0.1–10×In

Trip Time: ≤10 ms (instantaneous); ±50 ms accuracy

I/O & Interfaces

Analog Outputs: 4 × 4–20 mA, isolated

Digital Inputs: 9 opto‑isolated (dry/wet contact, ≤1 ms response)

Relay Outputs: 6 Form C (5 A / 250 VAC)

RTD Inputs: 3‑wire; 100Ω Pt, 100/120Ω Ni, 10Ω Cu

Communication: RS‑232 (front, programming), RS‑485 (Modbus RTU); no Ethernet

Display & User Interface

Display: Enhanced 40‑character backlit LCD

Indicators: LED status (RUN, TRIP, ALARM, FAULT)

Keypad: Numeric/navigation for local programming

Mechanical & Environmental

Dimensions: 177.5 mm H × 128.5 mm W × 119 mm D

Mounting: DIN rail or panel mount

Enclosure: Flame‑retardant plastic; IP50 (front), IP20 (overall)

Operating Temp: -40°C to +60°C

Storage Temp: -40°C to +85°C

Humidity: 5–95% non‑condensing

Certifications: UL, CE, CSA, ATEX, IEC 60255

Metering & Diagnostics

Metering: 3‑phase current/voltage, power, energy, frequency, PF, demand

Diagnostics: Event log (512 events), fault recorder, oscillography, pre‑trip data

Thermal Modeling: RTD biasing, cooling time constants, start inhibit

Core Functions

Comprehensive Motor Protection: Detects electrical/thermal faults to prevent damage and downtime.

Precision Monitoring: Real‑time tracking of electrical parameters and winding temperature via RTDs.

Flexible Control: Configurable start/stop logic, overload curves, and fault responses.

SCADA Integration: Modbus RTU over RS‑485 for remote monitoring/control.

Enhanced Local Operation: Larger LCD for clear diagnostics and programming.

Applications

Oil & Gas: Pumps, compressors, fans (medium‑voltage)

Power Utilities: Plant auxiliaries, substation motors

Metallurgy: Steel mills, heavy‑duty process motors

Chemical/Petrochemical: Critical process motor protection

Water Treatment: Pumps, blowers in municipal/industrial facilities

Usage & Maintenance

Installation: Mount on DIN rail/panel; wire CT/VT, control power, RTDs, and communications.

Programming: Use front keypad or connect to EnerVista 469 software via RS‑232.

Configuration: Set CT/VT ratios, protection curves, RTD types, and I/O mapping.

Maintenance: Inspect terminals annually; update firmware periodically; verify settings after system changes.


Get a Quote