JANCD-RY01 Relay Output Board
Description
1.1 Overview
1.2 Basic Specifications
Model Number: JANCD-RY01 (also DF8000045)
Manufacturer: Yaskawa Electric / Motoman
Applicable System: Motoman XRC Robot Controller
Board Type: Relay Output PCB
Revision: Standard revision (no common sub-rev)
Status: Discontinued (obsolete; used/refurbished only)
Weight: Approx. 1.0 kg (2.2 lbs)
Country of Origin: Japan
2. Electrical & Environmental Ratings
2.1 Relay Specifications
Output Type: Isolated dry-contact relays
Rated Voltage: 250 VAC max
Rated Current: 10 A per channel (resistive load)
Contact Configuration: SPST-NO (normally open)
Coil Voltage: 24 VDC (controller backplane)
2.2 Power Supply
Input Voltage: 24 VDC ±10% (backplane-fed)
Power Consumption: ~10 W (max)
2.3 Environmental Conditions
Operating Temperature: 0 °C to +40 °C
Storage Temperature: 0 °C to +50 °C
Relative Humidity: 5%–80% RH (non-condensing)
Maximum Altitude: 1,000 m above sea level
3. Functional Description
3.1 Core Functions
- Isolated Relay Outputs
Provides 8 channels of isolated NO relay contacts.
Switches high-power external loads separate from robot control circuits.
- Load Switching Control
Controls welding peripherals: gas valves, wire feeders, coolant pumps.
Drives external contactors, alarms, and process interlocks.
- Status Indication
On-board LEDs for each channel: ON = relay energized.
Enables quick visual diagnostics of output status.
- Bus Communication
Communicates with XRC main boards (e.g., JANCD-XEW01/02) via internal bus.
Receives on/off commands from robot program or teach pendant.
4. Compatibility & Installation
4.1 Compatibility
Exclusive Compatibility: Motoman XRC series robot controllers (all applications).
Incompatible With: NX100, NXC100, DX series, and Yasnac CNC systems.
4.2 Installation Steps
Power Off: Disconnect controller power; wait ≥5 minutes for capacitor discharge.
ESD Protection: Use ESD wristband to prevent static damage.
Slot Insertion: Insert into dedicated I/O slot on XRC backplane.
Connector Wiring:
Wire common (COM) and normally open (NO) contacts to external loads.
Use appropriate gauge wire for 10 A / 250 VAC ratings.
Power On: Restore power; verify board recognition via teach pendant.
5. Maintenance & Safety
5.1 Maintenance Guidelines
Periodic Inspection: Every 3 months, check connectors and wiring for wear or loose terminals.
Cleaning: Use dry, lint-free cloth; avoid liquid cleaners.
Relay Life: Rated for ~100,000 operations (resistive load); replace if contacts burn or stick.
5.2 Safety Precautions
High Voltage Warning: Relay contacts may carry 250 VAC; de-energize external circuits before servicing.
Qualified Personnel: Installation/maintenance only by certified technicians.
Static Sensitivity: Always use ESD protection when handling the board.
6. Troubleshooting
| Symptom | Possible Cause | Remedy |
|---|---|---|
| No relay actuation | Loose backplane connector | Re-seat board; tighten connectors |
| Relay chatters | Low 24 VDC supply | Check controller power supply |
| No output voltage | Wired to NC (wrong terminal) | Verify NO/COM wiring |
| LED ON but no load | Burned relay contacts | Replace JANCD-RY01 |
Get a Quote