JANCD-MTV
June 01, 2026

JANCD-MTV

JANCD-MTV is a general name for a series of relay output / control interface boards by Yaskawa Motoman, mainly including JANCD-MTV01 and JANCD-MTV02. They are used in Motoman XRC / MRC robot controllers to handle external I/O, safety interlocks, and load switching. All variants are discontinued (EOL); only used/refurbished units are available.

Description

1. General Description

JANCD-MTV is a general name for a series of relay output / control interface boards by Yaskawa Motoman, mainly including JANCD-MTV01 and JANCD-MTV02. They are used in Motoman XRC / MRC robot controllers to handle external I/O, safety interlocks, and load switching. All variants are discontinued (EOL); only used/refurbished units are available.

2. Basic Information

  • Model: JANCD-MTV (MTV01 / MTV02)

  • Manufacturer: Yaskawa Electric (Motoman)

  • Type: Relay output / external control interface board

  • Applicable: Motoman XRC, MRC robot controllers

  • Status: Discontinued, EOL

  • MTV01: 5 fused relays, 24 VDC, spring terminals

  • MTV02: Enhanced relay driver, higher current rating

  • Weight (MTV01): approx. 1.81 kg

3. Technical Specifications

  • Power: 24 VDC (from controller backplane)

  • Relays (MTV01): 5 fused relay outputs

  • Connection: Spring terminal blocks (field wiring friendly)

  • Operating Temp: 0 °C to +40 °C

  • Humidity: 5%–80% RH, non-condensing

  • Altitude: Up to 1,000 m above sea level

4. Key Functions

  • External load control: Switches 24 VDC loads (valves, contactors, alarms) via on-board relays.

  • Safety interlock: Routes emergency stop, door interlock, and safety relay signals.

  • System I/O expansion: Provides isolated relay outputs for external automation devices.

  • Fused protection: Each relay channel has a fuse to protect against short circuits.

5. MTV01 vs MTV02

  • MTV01: Standard 5-relay board, basic I/O and interlock.

  • MTV02: Upgraded, higher relay current rating, improved surge suppression, direct pin-for-pin replacement for MTV01.

6. Compatibility

  • Fully compatible with Motoman XRC, MRC series controllers.

  • Not compatible with DX, FS, YRC or non-Yaskawa systems.

7. Installation & Safety

  • Power off before installation; no hot swapping.

  • Use grounded ESD wristband to avoid static damage.

  • Insert into dedicated slot, tighten screws.

  • Separate low‑voltage signal wires from high‑voltage cables.

  • Only qualified technicians should perform maintenance.


Get a Quote