Honeywell 51201420-001 (FTA Cable 1 Meter)
June 01, 2026

Honeywell 51201420-001 (FTA Cable 1 Meter)

Product Introduction The 51201420-001 is a 1-meter FTA (Field Terminal Assembly) cable for Honeywell Experion PKS and TDC3000/TPS DCS systems. It connects I/O modules to field terminal blocks, transmitting control signals and power between the control room and field devices.

Description

Model Explanation

  • 51201420: Base part number (FTA cable series)

  • ‑001: Cable length = 1 meter

  • Compatible Lengths: -002 (2m), -006 (6m), -008 (8m), -010 (10m), -015 (15m)

  • Type: Pre-assembled, shielded, twisted-pair FTA cable

Technical Parameters

  • Cable Type: Multi-core, shielded, twisted-pair

  • Length: 1 meter

  • Connector A: Honeywell I/O module edge connector (male)

  • Connector B: FTA terminal block header (female)

  • Insulation: PVC, flame-retardant

  • Shielding: Overall foil + braid shield (EMI/RFI protection)

  • Operating Temp: -20°C to +70°C

  • Voltage Rating: 300V

  • Current Rating: 5A per conductor

  • Certifications: CE, UL, CSA, RoHS

Interface & Communication Configuration

  • Module End: Direct plug-in to Honeywell Series C I/O modules (e.g., C300)

  • FTA End: Crimped/pinned header for FTA terminal blocks

  • Pinout: Custom per I/O signal type (AI/AO/DI/DO)

  • Shield Ground: Single-point grounding at FTA end

  • Compatibility: All Honeywell FTA-compatible I/O modules

Core Functions

  • Signal Transmission: Reliable transfer of analog/digital I/O signals

  • Noise Protection: Shielded design minimizes EMI/RFI interference

  • Pre-Assembled: Factory-terminated for quick, error-free installation

  • Standardized Connection: Ensures interoperability between modules and FTAs

  • Durability: Industrial-grade materials for long-term use in control cabinets

Application Scope

  • Honeywell Experion PKS C200/C300 I/O racks

  • TDC3000/TPS UCN system FTA panels

  • Process industries: oil & gas, refining, chemical, power, pharmaceuticals

  • Control room cabinet wiring (module ↔ FTA)

  • New installations or replacement of damaged FTA cables

Operation & Maintenance Instructions

  • Route cable in clean, dry cabinet; avoid sharp bends (<90°)

  • Plug module end firmly into I/O module; secure with latch

  • Connect FTA end to terminal block; tighten screws to torque spec

  • Maintain single-point shield ground at FTA end (do not ground both ends)

  • Inspect periodically for wear, damage, or loose connections


Get a Quote